Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2001 Feb;46(1):23-30.

[A scanning electron microscopy study of the surface of porous-textured breast implants and their capsules. Description of the "velcro" effect of porous-textured breast prostheses]

[Article in French]
Affiliations
  • PMID: 11233731
Comparative Study

[A scanning electron microscopy study of the surface of porous-textured breast implants and their capsules. Description of the "velcro" effect of porous-textured breast prostheses]

[Article in French]
A Danino et al. Ann Chir Plast Esthet. 2001 Feb.

Abstract

The efficacy of breast prosthesis texturing in the prevention of capsular contracture has been established for about 20 years. This successful procedure has led to the development and marketing of a number of different models. In the present study, four porous-textured breast prostheses have been examined: the Arion monoblock implant, the CUI (McGahn), the Biocell (Mcgahn), and the Sebbin LS21. Scanning electron microscopic (SEM) investigation of the implant surfaces of the different prostheses was carried out on new samples received from the manufacturers. During a prospective study on eight patients, capsule samples corresponding to the four above-mentioned prostheses were taken to determine whether a secondary intervention was necessary for correction of asymmetry or malpositioning. These samples were analyzed by SEM to investigate whether there could be a correlation between prosthesis texturing and the aspect of the corresponding capsules. Significant ultrastructural differences were found between the various prostheses examined: the results showed that only the CUI and Biocell prostheses presented a mirror image of the capsule texturing, with a correspondence between the depressions on the prosthesis and the contacts on the capsule. This finding seems to be linked to the existence of a critical size for the pores that constitute the implant surface. This observation led to the hypothesis of an adhesive "velcro" effect between the prosthesis and its capsule. Although the latter may not be directly linked to the prevention of capsular contracture it can, however, have a major effect on implant stabilization in cases of primary breast reconstruction and in possible secondary adjustments of asymmetry and malpositioning.

PubMed Disclaimer

LinkOut - more resources