Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2001 Mar;16(3):245-51.
doi: 10.1016/s0268-0033(00)00089-9.

Mechanical properties of the human achilles tendon

Affiliations

Mechanical properties of the human achilles tendon

T A Wren et al. Clin Biomech (Bristol). 2001 Mar.

Abstract

Objective: To determine whether the human Achilles tendon has higher material properties than other tendons and to test for strain rate sensitivity of the tendon.

Design: Mechanical testing of excised tendons.

Background: While the human Achilles tendon appears to experience higher in vivo stresses than other tendons, it is not known how the Achilles tendon's material properties compare with the properties of other tendons.

Methods: Modulus, failure stress, and failure strain were measured for excised human Achilles tendons loaded at strain rates of 1% s(-1) and 10% s(-1). Paired t-tests were used to examine strain rate effects, and average properties from grouped data were used to compare the Achilles tendon's properties with properties reported in the literature for other tendons.

Results: Failure stress and failure strain were higher at the faster strain rate, but no significant difference in modulus was observed. At the 1% s(-1)rate, the mean modulus and failure stress were 816 MPa (SD, 218) and 71 MPa (SD, 17), respectively. The failure strain was 12.8% (SD, 1.7) for the bone-tendon complex and 7.5% (SD, 1.1) for the tendon substance. At the 10% s(-1) rate, the mean modulus and failure stress were 822 MPa (SD, 211) and 86 MPa (SD, 24), respectively. The mean failure strain was 16.1% (SD, 3.6) for the bone-tendon complex and 9.9% (SD, 1.9) for the tendon substance. These properties fall within the range of properties reported in the literature for other tendons.

Conclusions: The material properties of the human Achilles tendon measured in this study are similar to the properties of other tendons reported in the literature despite higher stresses imposed on the Achilles tendon in vivo.

PubMed Disclaimer

Publication types

LinkOut - more resources