Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2001 Mar;13(3):397-401.
doi: 10.1002/jmri.1057.

Focal liver lesions: comparison of dual-phase CT and multisequence multiplanar MR imaging including dynamic gadolinium enhancement

Affiliations
Comparative Study

Focal liver lesions: comparison of dual-phase CT and multisequence multiplanar MR imaging including dynamic gadolinium enhancement

R C Semelka et al. J Magn Reson Imaging. 2001 Mar.

Abstract

The purpose of this study was to compare dual-phase spiral computed tomography (CT) and magnetic resonance imaging (MRI) using dynamic gadolinium enhancement for liver lesion detection and characterization. Twenty-two consecutive patients underwent dual-phase spiral CT and MRI for the evaluation of focal liver disease within a 1-month period. Spiral CT and MR images were interpreted prospectively, in a blinded fashion by separate, individual, experienced investigators, to determine lesion detection and characterization. Liver lesions were confirmed by surgery and pathology in 6 patients, and by clinical and imaging follow-up in the other 16 patients. Pathological correlation of a primary extrahepatic malignancy was available in 5 of the 16 patients who had metastatic liver disease. Spiral CT and MRI detected 53 and 63 lesions, and characterized 39 and 62 true positive lesions, respectively. A kappa statistic test was applied to assess agreement between MR and CT results. MR versus CT for lesion detection resulted in a kappa statistic of 0.54 (95% confidence interval), indicating moderate agreement, and 0.32 (95% confidence interval) for lesion characterization, indicating only slight agreement. More lesions were detected on MR images than CT images in 6 (27%) patients, with lesions detected only on MR images in 4 (18%) patients. More lesions were characterized on MR images in 9 (41%) patients. In 9 patients with a discrepancy between MR and CT findings, the MR images added information considered significant to patient management in all 9 cases. MRI was moderately superior to dual-phase spiral CT for lesion detection, and was markedly superior for lesion characterization, with these differences having clinical significance.

PubMed Disclaimer

Publication types

MeSH terms