Analysis of ambulatory duodenogastroesophageal reflux monitoring
- PMID: 11258576
- DOI: 10.1023/a:1005667731289
Analysis of ambulatory duodenogastroesophageal reflux monitoring
Abstract
Some methodological in vitro observations concerning bile reflux monitoring (Bilitec) suggested that Bilitec monitoring is underestimating reflux in an acid environment. Moreover, other studies showed that the area above the cutoff level of bilirubin absorbance would provide an adequate quantitative marker for reflux of duodenal contents. Our aim was to study whether correction for intraesophageal acidity and the area above cutoff during Bilitec monitoring affects the results and the correlation with pH measurement and esophageal lesions. In 84 patients (46 men; mean age 46 +/- 2.7 years) evaluated for suspected gastroesophageal reflux disease, we performed ambulatory 24-hr esophageal pH and Bilitec monitoring after an upper gastrointestinal endoscopy. We obtained total area, percent total time, and correction by computer software. The correction factor for bilirubin absorbance was based on literature data for acidified bile (0.06 for pH < 3.6; 0.21 for pH < 2.6). Endoscopy revealed esophagitis grade 1-2 (E1-2) and 3-4 (E3-4) in 23 and 16 patients, respectively. A progressive increase of mixed (acid + bile) reflux occurred with increasing severity of endoscopic lesions (E3-4 vs no esophagitis, P < 0.05). A pathologic Bilitec monitoring result was present in the same 35 patients before and after correction and the correlation between the pH measurement and percent time of bile reflux was not improved by correction for intraesophageal pH (r = 0.386 and r = 0.391; P < 0.05). The total area of bilirubin absorbance above 0.14 (abs x min) was 7.8 +/- 2.2 in patients without esophagitis, and 11.7 +/- 4.4 and 17.0 +/- 4.2 in the E1-2 and E3-4 groups, respectively (E3-4 vs no esophagitis, P < 0.05). The correlation between the Bilitec monitoring and pH measurement regarding percent (r = 0.427, P < 0.01) or area of time below 4 (r = 0.280, P < 0.05) was not improved by considering the area of bilirubin absorbance above the cutoff level. Correction for intraesophageal pH has only a minor effect on the results of ambulatory Bilitec monitoring. Taking into account the surface rather than the percent of time above the cutoff level for bilirubin absorbance does not improve the correlation of Bilitec with acid reflux and with esophageal lesions.
Similar articles
-
Dietary restrictions during ambulatory monitoring of duodenogastroesophageal reflux.Dig Dis Sci. 2003 Jul;48(7):1213-20. doi: 10.1023/a:1024130419914. Dig Dis Sci. 2003. PMID: 12870775 Clinical Trial.
-
Biliary reflux and non-acid reflux are two distinct phenomena: a comparison between 24-hour multichannel intraesophageal impedance and bilirubin monitoring.Scand J Gastroenterol. 2007 Sep;42(9):1031-9. doi: 10.1080/00365520701245645. Scand J Gastroenterol. 2007. PMID: 17710667
-
Gastric bile monitoring: an in vivo and in vitro study of Bilitec reliability.Scand J Gastroenterol. 2002 Nov;37(11):1334-7. doi: 10.1080/003655202761020632. Scand J Gastroenterol. 2002. PMID: 12465734
-
Duodenogastroesophageal reflux and methods to monitor nonacidic reflux.Am J Med. 2001 Dec 3;111 Suppl 8A:160S-168S. doi: 10.1016/s0002-9343(01)00827-0. Am J Med. 2001. PMID: 11749944 Review.
-
Review article: modern technology in the diagnosis of gastro-oesophageal reflux disease--Bilitec, intraluminal impedance and Bravo capsule pH monitoring.Aliment Pharmacol Ther. 2006 Mar;23 Suppl 1:12-24. doi: 10.1111/j.1365-2036.2006.02800.x. Aliment Pharmacol Ther. 2006. PMID: 16483266 Review.
Cited by
-
Kyoto international consensus report on anatomy, pathophysiology and clinical significance of the gastro-oesophageal junction.Gut. 2022 Aug;71(8):1488-1514. doi: 10.1136/gutjnl-2022-327281. Epub 2022 Jun 20. Gut. 2022. PMID: 35725291 Free PMC article.
-
Duodenogastric reflux after esophagectomy and gastric pull-up: the effect of the route of reconstruction.World J Surg. 2005 Feb;29(2):174-81. doi: 10.1007/s00268-004-7568-0. World J Surg. 2005. PMID: 15650801
-
Comparative evaluation of intragastric bile acids and hepatobiliary scintigraphy in the diagnosis of duodenogastric reflux.World J Gastroenterol. 2013;19(14):2187-96. doi: 10.3748/wjg.v19.i14.2187. World J Gastroenterol. 2013. PMID: 23599645 Free PMC article.
-
Gastroesophageal reflux in cirrhotic patients without esophageal varices.World J Gastroenterol. 2011 Apr 7;17(13):1753-8. doi: 10.3748/wjg.v17.i13.1753. World J Gastroenterol. 2011. PMID: 21483637 Free PMC article.
-
Dietary restrictions during ambulatory monitoring of duodenogastroesophageal reflux.Dig Dis Sci. 2003 Jul;48(7):1213-20. doi: 10.1023/a:1024130419914. Dig Dis Sci. 2003. PMID: 12870775 Clinical Trial.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical