Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2001 Mar-Apr;29(2):145-62.
doi: 10.1177/026119290102900208.

The red blood cell phototoxicity test (photohaemolysis and haemoglobin oxidation): EU/COLIPA validation programme on phototoxicity (phase II)

Affiliations

The red blood cell phototoxicity test (photohaemolysis and haemoglobin oxidation): EU/COLIPA validation programme on phototoxicity (phase II)

W J Pape et al. Altern Lab Anim. 2001 Mar-Apr.

Abstract

In the EU/COLIPA validation programme on "Photoirritation in vitro", two core tests and a number of mechanistically based tests were carried out to examine their suitability as regulatory tests for phototoxicity testing. In the meantime, one core test, the 3T3 neutral red uptake phototoxicity test (NRU PT) has been validated and has been accepted by ECVAM and the European Commission. The second core test, the red blood cell phototoxicity test (Photo-RBC test), has passed through a prevalidation process during this programme. This test protocol combines two endpoints, photohaemolysis and met-haemoglobin (met-Hb) formation. These endpoints are determined by measuring changes in the optical density of the haemoglobin spectrum at 525 nm and 630 nm, respectively. In addition, a prediction model was inserted into the Standard Operating Procedure (SOP) with two cut-off values: a photohaemolysis factor (PHF) > or = 3.0 for photohaemolysis, and a deltaOD(max) > or = 0.05 for met-Hb formation. Three laboratories agreed to implement the SOP and to perform the study by testing 30 selected test chemicals (25 phototoxicants and 5 non- phototoxic chemicals). The outcome of the study presents a good overall fit, including acceptable accuracy, sensitivity, and positive predictivity. The specificity and the negative predictivity are comparably low, due to the low number of non-phototoxic substances among the test chemicals. Further analysis of the data showed that the transfer of the SOP from between laboratories could have been more efficient. The results, especially of the lead laboratory, clearly indicate that an experienced laboratory can handle the SOP with high predictivity for phototoxicants and non-phototoxic substances. Finally, it was concluded that the combined Photo-RBC test can be considered as a second in vitro test, which can be used advantageously to obtain some mechanistic information, in particular on photodynamic effects on cellular proteins and biomembranes.

PubMed Disclaimer

Publication types

LinkOut - more resources