Heparin therapy during extracorporeal circulation. II. The use of a dose-response curve to individualize heparin and protamine dosage
- PMID: 1127967
Heparin therapy during extracorporeal circulation. II. The use of a dose-response curve to individualize heparin and protamine dosage
Abstract
Because the administration of heparin and protamine according to a set protocol will fail to anticoagulate safely or neutralize appropriately a significant number of patients, a method of monitoring heparin therapy during cardiopulmonary bypass is presented. A dose response curve relating heparin dosage to its effect on the activated coagulation time (ACT) can be determined with sufficient accuracy for clinical purposes from three ACT's. Preparation of such a curve makes it possible to maintain anticoagulation in a safe range during bypass and minimizes the number of monitoring tests of coagulation required. At the conclusion of bypass, this curve can be used to predict the precise amount of protamine needed for neutralization. Freed from the confusing effects of hyperheparinemia or protamine excess, the physician can diagnose and treat postoperative bleeding problems much more readily.
Similar articles
-
Heparin therapy during extracorporeal circulation. I. Problems inherent in existing heparin protocols.J Thorac Cardiovasc Surg. 1975 May;69(5):674-84. J Thorac Cardiovasc Surg. 1975. PMID: 1127966
-
Heparin administration during extracorporeal circulation: heparin rebound and postoperative bleeding.J Thorac Cardiovasc Surg. 1979 Jul;78(1):95-102. J Thorac Cardiovasc Surg. 1979. PMID: 449391
-
Complications of heparin therapy.Surg Gynecol Obstet. 1975 May;140(5):789-96. Surg Gynecol Obstet. 1975. PMID: 1170648
-
Safety issues in heparin and protamine administration for extracorporeal circulation.J Cardiothorac Vasc Anesth. 1998 Apr;12(2 Suppl 1):17-20. J Cardiothorac Vasc Anesth. 1998. PMID: 9583571 Review.
-
Anticoagulation for pediatric mechanical circulatory support.Pediatr Crit Care Med. 2013 Jun;14(5 Suppl 1):S37-42. doi: 10.1097/PCC.0b013e318292dfa7. Pediatr Crit Care Med. 2013. PMID: 23735984 Review.
Cited by
-
Labeling stem cells with superparamagnetic iron oxide nanoparticles: analysis of the labeling efficacy by microscopy and magnetic resonance imaging.Methods Mol Biol. 2012;906:239-52. doi: 10.1007/978-1-61779-953-2_18. Methods Mol Biol. 2012. PMID: 22791437 Free PMC article.
-
Protamine/heparin optical nanosensors based on solvatochromism.Chem Sci. 2021 Nov 15;12(47):15596-15602. doi: 10.1039/d1sc04930e. eCollection 2021 Dec 8. Chem Sci. 2021. PMID: 35003589 Free PMC article.
-
Lack of correlation between activated clotting time and plasma heparin during cardiopulmonary bypass.Ann Surg. 1981 Jan;193(1):105-11. doi: 10.1097/00000658-198101000-00017. Ann Surg. 1981. PMID: 6970015 Free PMC article.
-
Heparin concentration-based anticoagulation for cardiac surgery fails to reliably predict heparin bolus dose requirements.Anesth Analg. 2010 Oct;111(4):849-55. doi: 10.1213/ANE.0b013e3181b79d09. Epub 2009 Oct 27. Anesth Analg. 2010. PMID: 19861367 Free PMC article.
-
Evaluation of the use of a heparin dose-response test in dogs to determine the optimal heparin dose during intravascular procedures and assessment of the in vitro heparin response in healthy dogs.Vet Med Sci. 2024 May;10(3):e1326. doi: 10.1002/vms3.1326. Epub 2023 Nov 21. Vet Med Sci. 2024. PMID: 37987511 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Other Literature Sources