Clinical Trial
. 2001 Jan;27(1):301-5.
doi: 10.1007/s001340000792.

The Internal jugular veins are asymmetric. Usefulness of ultrasound before catheterization

Affiliations
Clinical Trial

The Internal jugular veins are asymmetric. Usefulness of ultrasound before catheterization

D Lichtenstein et al. Intensive Care Med. 2001 Jan.

Abstract

Objective: To demonstrate an asymmetry of the internal jugular veins, a finding which will have consequences for catheterization.

Design: Prospective study.

Setting: The medical ICU of a university-affiliated teaching hospital.

Patients: Eighty critically ill consecutive patients.

Intervention: Measurement of the cross-sectional area of the internal jugular veins. Search for an asymmetry, defined as an area at least twice that of the contralateral vein.

Results: An asymmetry was noted in 62.5% of the patients. The dominant vein was the right in only 68 % of these cases. In addition, 23% of the 160 jugular internal veins had an area of 0.4 cm2 or less.

Conclusions: Using a simple technique, ultrasound identifies the dominant internal jugular vein, thus indicating the safer side before blind catheterization.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources