Comparison of BD Vacutainer SST Plus Tubes with BD SST II Plus Tubes for common analytes
- PMID: 11282105
- DOI: 10.1016/s0009-8981(01)00396-5
Comparison of BD Vacutainer SST Plus Tubes with BD SST II Plus Tubes for common analytes
Abstract
Serum separator tubes were introduced 25 years ago and are widely used in the clinical laboratory today for routine collection of blood. These tubes have gained widespread acceptance due to the advantage of the barrier gel that facilitates rapid separation of serum from cellular constituents of blood and thus reduces hemolysis. However, there are some limitations associated with gel tubes (i.e., gel stability and analyte incompatibilities). The serum separator BD SST tubes manufactured by BD are widely used in clinical laboratories. Recently, BD has developed a new barrier gel, which is superior to the existing gel. We studied the stability of common analytes when serum specimens were stored in the new BD SST II tubes by comparing the performance with the existing BD SST tubes. We did not observe any significant reduction in concentrations of 42 commonly ordered analytes using the new BD SST II tubes. Significant differences were noted at low serum volumes for estradiol in both tube types over time. We conclude that the new BD SST II tubes are suitable for collection of blood and storage of serum for commonly ordered laboratory tests.
Similar articles
-
Evaluation of BD Vacutainer SST™ II Plus tubes for common tumor marker tests by Roche Diagnostics Modular E 170 analyzer.J Clin Lab Anal. 2010;24(6):418-21. doi: 10.1002/jcla.20422. J Clin Lab Anal. 2010. PMID: 21089174 Free PMC article.
-
Stability of therapeutic drugs in serum collected in vacutainer serum separator tubes containing a new gel (SST II).Ther Drug Monit. 2001 Jun;23(3):259-62. doi: 10.1097/00007691-200106000-00013. Ther Drug Monit. 2001. PMID: 11360035
-
Evaluation of BD Vacutainer SST™ II plus tubes for special proteins testing.J Clin Lab Anal. 2011;25(3):203-6. doi: 10.1002/jcla.20458. J Clin Lab Anal. 2011. PMID: 21567469 Free PMC article.
-
[Comparison of two new plastic tubes (Sekisui INSEPACK and Green Cross Green Vac-Tube) with BD Vacutainer tubes for 49 analytes].Korean J Lab Med. 2007 Feb;27(1):69-75. doi: 10.3343/kjlm.2007.27.1.69. Korean J Lab Med. 2007. PMID: 18094554 Korean.
-
Evaluation of the BD Vacutainer PST II blood collection tube for special chemistry analytes.Clin Chem Lab Med. 2009;47(3):358-61. doi: 10.1515/cclm.2009.072. Clin Chem Lab Med. 2009. PMID: 19676149
Cited by
-
Spatial heterogeneity of peri-tumoural lipid composition in postmenopausal patients with oestrogen receptor positive breast cancer.Sci Rep. 2024 Feb 26;14(1):4699. doi: 10.1038/s41598-024-55458-y. Sci Rep. 2024. PMID: 38409583 Free PMC article.
-
Long non-coding RNA NBAT1, TUG1, miRNA-335, and miRNA-21 as potential biomarkers for acute ischemic stroke and their possible correlation to thyroid hormones.Front Mol Biosci. 2022 Sep 30;9:914506. doi: 10.3389/fmolb.2022.914506. eCollection 2022. Front Mol Biosci. 2022. PMID: 36250025 Free PMC article.
-
Circulating miR-206, miR-181b, and miR-21 as promising biomarkers in hypothyroidism and their relationship to related hyperlipidemia and hepatic steatosis.Front Mol Biosci. 2024 Feb 2;11:1307512. doi: 10.3389/fmolb.2024.1307512. eCollection 2024. Front Mol Biosci. 2024. PMID: 38370005 Free PMC article.
-
Fibrin clot interference in a human chorionic gonadotrophin assay causing a false Down syndrome screening result.Biochem Med (Zagreb). 2023 Feb 15;33(1):011001. doi: 10.11613/BM.2023.011001. Biochem Med (Zagreb). 2023. PMID: 36817855 Free PMC article.
-
Paraxanthine provides greater improvement in cognitive function than caffeine after performing a 10-km run.J Int Soc Sports Nutr. 2024 Dec;21(1):2352779. doi: 10.1080/15502783.2024.2352779. Epub 2024 May 9. J Int Soc Sports Nutr. 2024. PMID: 38725238 Free PMC article. Clinical Trial.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Miscellaneous