Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2001 Jan-Mar;16(1):27-30.
doi: 10.1177/172460080101600103.

Relationship between mesenteric and peripheral blood levels of CA 19-9 in patients with colorectal cancer

Affiliations
Free article
Comparative Study

Relationship between mesenteric and peripheral blood levels of CA 19-9 in patients with colorectal cancer

N M Forones et al. Int J Biol Markers. 2001 Jan-Mar.
Free article

Abstract

Introduction: CA19-9 is one of the most important tumor markers used in patients with colorectal cancer, mainly in radical surgery follow-up.

Aim: The purpose of this study was to evaluate the preoperative CA19-9 level obtained from a peripheral vein (PV) and compare it to the level obtained from the mesenteric vein (MV).

Materials and methods: Blood was collected from a PV of the arm and from the MV of 59 patients with colorectal cancer before primary surgery. Of these 59 patients fourteen had stage I disease, 10 stage II, 22 stage III, and 13 stage IV. CA19-9 was determined in serum by immunoenzymatic assay (Abbott Diagnostica).

Results: Fifteen patients (24%) had elevated serum levels of CA19-9 in the MV and 13 (22%) in the PV. None of the stage I or II patients had elevated serum levels of CA19-9. There were no differences between marker levels in blood collected from the MV or PV, independent of clinical stage. The CA19-9 values obtained from the MV differed significantly in the different stages of the disease according to the Kruskal-Wallis analysis (p=0.026); this difference was not statistically significant (p=0.08) in serum from the PV. There was no correlation between venous infiltration by the tumor and positivity of CA19-9 serum levels collected from the mesenteric vein. We observed a close correlation between the serum levels of CA19-9 collected from the PV and from the MV (r=0.9).

Conclusion: The current study demonstrates a close correlation between the serum levels of CA19-9 collected from a peripheral vein and from the mesenteric vein. Our results confirmed the poor sensitivity of serum CA19-9 at diagnosis, independent of the collection site.

PubMed Disclaimer

Publication types

Substances

LinkOut - more resources