Qualitative and quantitative evaluation of six algorithms for correcting intensity nonuniformity effects
- PMID: 11304088
- DOI: 10.1006/nimg.2001.0756
Qualitative and quantitative evaluation of six algorithms for correcting intensity nonuniformity effects
Abstract
The desire to correct intensity nonuniformity in magnetic resonance images has led to the proliferation of nonuniformity-correction (NUC) algorithms with different theoretical underpinnings. In order to provide end users with a rational basis for selecting a given algorithm for a specific neuroscientific application, we evaluated the performance of six NUC algorithms. We used simulated and real MRI data volumes, including six repeat scans of the same subject, in order to rank the accuracy, precision, and stability of the nonuniformity corrections. We also compared algorithms using data volumes from different subjects and different (1.5T and 3.0T) MRI scanners in order to relate differences in algorithmic performance to intersubject variability and/or differences in scanner performance. In phantom studies, the correlation of the extracted with the applied nonuniformity was highest in the transaxial (left-to-right) direction and lowest in the axial (top-to-bottom) direction. Two of the six algorithms demonstrated a high degree of stability, as measured by the iterative application of the algorithm to its corrected output. While none of the algorithms performed ideally under all circumstances, locally adaptive methods generally outperformed nonadaptive methods.
Copyright 2001 Academic Press.
Similar articles
-
Magnetic resonance image tissue classification using a partial volume model.Neuroimage. 2001 May;13(5):856-76. doi: 10.1006/nimg.2000.0730. Neuroimage. 2001. PMID: 11304082
-
Twenty new digital brain phantoms for creation of validation image data bases.IEEE Trans Med Imaging. 2006 Nov;25(11):1410-6. doi: 10.1109/TMI.2006.883453. IEEE Trans Med Imaging. 2006. PMID: 17117770
-
Interplay between intensity standardization and inhomogeneity correction in MR image processing.IEEE Trans Med Imaging. 2005 May;24(5):561-76. doi: 10.1109/TMI.2004.843256. IEEE Trans Med Imaging. 2005. PMID: 15889544
-
Imaging artifacts at 3.0T.J Magn Reson Imaging. 2006 Oct;24(4):735-46. doi: 10.1002/jmri.20698. J Magn Reson Imaging. 2006. PMID: 16958057 Review.
-
A review of methods for correction of intensity inhomogeneity in MRI.IEEE Trans Med Imaging. 2007 Mar;26(3):405-21. doi: 10.1109/TMI.2006.891486. IEEE Trans Med Imaging. 2007. PMID: 17354645 Review.
Cited by
-
vol2Brain: A New Online Pipeline for Whole Brain MRI Analysis.Front Neuroinform. 2022 May 24;16:862805. doi: 10.3389/fninf.2022.862805. eCollection 2022. Front Neuroinform. 2022. PMID: 35685943 Free PMC article.
-
Restoration of MRI Data for Field Nonuniformities using High Order Neighborhood Statistics.Proc SPIE Int Soc Opt Eng. 2007 Mar 5;6512:65121L. doi: 10.1117/12.711533. Proc SPIE Int Soc Opt Eng. 2007. PMID: 18193095 Free PMC article.
-
Intensity inhomogeneity correction of SD-OCT data using macular flatspace.Med Image Anal. 2018 Jan;43:85-97. doi: 10.1016/j.media.2017.09.008. Epub 2017 Oct 12. Med Image Anal. 2018. PMID: 29040910 Free PMC article.
-
Online resource for validation of brain segmentation methods.Neuroimage. 2009 Apr 1;45(2):431-9. doi: 10.1016/j.neuroimage.2008.10.066. Epub 2008 Nov 25. Neuroimage. 2009. PMID: 19073267 Free PMC article.
-
Evaluation of a metal artifact reduction algorithm applied to post-interventional flat detector CT in comparison to pre-treatment CT in patients with acute subarachnoid haemorrhage.Eur Radiol. 2017 Jan;27(1):88-96. doi: 10.1007/s00330-016-4351-1. Epub 2016 Apr 16. Eur Radiol. 2017. PMID: 27085699
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Miscellaneous