Incubators versus mothers' arms: body temperature conservation in very-low-birth-weight premature infants
- PMID: 11308105
- DOI: 10.1111/j.1552-6909.2001.tb01531.x
Incubators versus mothers' arms: body temperature conservation in very-low-birth-weight premature infants
Abstract
Objective: To determine whether there is a significant difference between the temperatures of very-low-birth-weight (VLBW) premature infants in the incubator and in the mothers' arms.
Design: Repeated measures, with random assignment to treatment order and the infants serving as their own controls.
Setting: A 40-bed tertiary-level nursery in a university teaching hospital.
Participants: A convenience sample of 20 preterm infants weighing 1,095 to 1,500 g and from 30 to 37 weeks postconceptional age. The infants were screened for factors that would interfere with temperature maintenance.
Main outcome measures: Axillary temperatures were measured with an electronic thermometer for equal periods of time in incubators and mothers' arms. The mean temperature differences between the two study conditions were compared using two-tailed t tests and repeated analysis of variance (ANOVA). Weight was monitored and analyzed for evidence of increased metabolic activity.
Results: No significant variations were found in the infants' mean temperatures in the incubator, but the infants were significantly warmer while in their mothers' arms.
Conclusion: VLBW premature infants can maintain a stable temperature in their mothers' arms without evidence of increased metabolic activity. Nurses can encourage mothers to hold their infants without fear of cold stress or weight loss.
Similar articles
-
Kangaroo care compared to incubators in maintaining body warmth in preterm infants.Biol Res Nurs. 2000 Jul;2(1):60-73. doi: 10.1177/109980040000200107. Biol Res Nurs. 2000. PMID: 11232513 Clinical Trial.
-
[Incubator care versus "open care" in the warming bed for very small premature infants].Kinderkrankenschwester. 1999 May;18(5):195-200. Kinderkrankenschwester. 1999. PMID: 10514661 Clinical Trial. German. No abstract available.
-
Optimal body temperature in transitional extremely low birth weight infants using heart rate and temperature as indicators.J Obstet Gynecol Neonatal Nurs. 2010 Jan-Feb;39(1):3-14. doi: 10.1111/j.1552-6909.2009.01087.x. J Obstet Gynecol Neonatal Nurs. 2010. PMID: 20409098 Free PMC article.
-
Optimizing the neonatal thermal environment.Neonatal Netw. 2006 Jul-Aug;25(4):251-60. doi: 10.1891/0730-0832.25.4.251. Neonatal Netw. 2006. PMID: 16913236 Review.
-
Thermoregulation and heat loss prevention after birth and during neonatal intensive-care unit stabilization of extremely low-birthweight infants.J Obstet Gynecol Neonatal Nurs. 2007 May-Jun;36(3):280-7. doi: 10.1111/j.1552-6909.2007.00149.x. J Obstet Gynecol Neonatal Nurs. 2007. PMID: 17489935 Review.
Cited by
-
Early detection of cold stress to prevent hypothermia: A narrative review.SAGE Open Med. 2023 May 13;11:20503121231172866. doi: 10.1177/20503121231172866. eCollection 2023. SAGE Open Med. 2023. PMID: 37197020 Free PMC article. Review.
-
A comparative study of maternal-neonate abdominal and kangaroo (skin-to-skin) skin contact immediately after birth on maternal attachment behaviors up to 2 months.J Educ Health Promot. 2018 Mar 1;7:42. doi: 10.4103/jehp.jehp_46_16. eCollection 2018. J Educ Health Promot. 2018. PMID: 29619393 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical