Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2001 Apr 24;103(16):2066-71.
doi: 10.1161/01.cir.103.16.2066.

Electrical storm presages nonsudden death: the antiarrhythmics versus implantable defibrillators (AVID) trial

Affiliations

Electrical storm presages nonsudden death: the antiarrhythmics versus implantable defibrillators (AVID) trial

D V Exner et al. Circulation. .

Abstract

Background: Electrical storm, multiple temporally related episodes of ventricular tachycardia (VT) or ventricular fibrillation (VF), is a frequent problem among recipients of implantable cardioverter defibrillators (ICDs). However, insufficient data exist regarding its prognostic significance.

Methods and results: This analysis includes 457 patients who received an ICD in the Antiarrhythmics Versus Implantable Defibrillators (AVID) trial and who were followed for 31 +/- 13 months. Electrical storm was defined as > or = 3 separate episodes of VT/VF within 24 hours. Characteristics and survival of patients surviving electrical storm (n = 90), those with VT/VF unrelated to electrical storm (n = 184), and the remaining patients (n = 183) were compared. The 3 groups differed in terms of ejection fraction, index arrhythmia, revascularization status, and baseline medication use. Survival was evaluated using time-dependent Cox modeling. Electrical storm occurred 9.2 +/- 11.5 months after ICD implantation, and most episodes (86%) were due to VT. Electrical storm was a significant risk factor for subsequent death, independent of ejection fraction and other prognostic variables (relative risk [RR], 2.4; 95% confidence interval [CI], 1.3 to 4.2; P = 0.003), but VT/VF unrelated to electrical storm was not (RR, 1.0; 95% CI, 0.6 to 1.7; P = 0.9). The risk of death was greatest 3 months after electrical storm (RR, 5.4; 95% Cl, 2.4 to 12.3; P = 0.0001) and diminished beyond this time (RR, 1.9; 95% CI, 1.0 to 3.6; P=0.04).

Conclusions: Electrical storm is an important, independent marker for subsequent death among ICD recipients, particularly in the first 3 months after its occurrence. However, the development of VT/VF unrelated to electrical storm does not seem to be associated with an increased risk of subsequent death.

PubMed Disclaimer

Publication types

MeSH terms

Substances