Quality assurance in radiotherapy of breast cancer--variability in planning target volume delineation
- PMID: 11321661
- DOI: 10.1080/028418601750071055
Quality assurance in radiotherapy of breast cancer--variability in planning target volume delineation
Abstract
The inter-physician and inter-patient variability in planning target volume delineation for the radiotherapy of breast cancer after conservative surgery is presented. Eleven experienced radiation oncologists determined the planning target volume (PTV) for four breast cancer patients. Delineation was based on CT slices taken at intervals of 15 mm. The variability in target volume delineation was determined by measuring the volumes in units of cc and the position of the drawn PTVs. Statistical analysis was based on X/R-charts and on Pareto chart and analysis. The maximum range in PTV for one patient was from 670 to 1,200 cc. The observations of three physicians were in excess of the warning limit altogether 18 times. The methods used in this study clearly reveal inter-physician variability in PTV delineation and widest variations found are not acceptable. Training targeted to some physicians and more detailed and unambiguous protocols for PTV delineation are needed.
Similar articles
-
Variability in target volume delineation on CT scans of the breast.Int J Radiat Oncol Biol Phys. 2001 Aug 1;50(5):1366-72. doi: 10.1016/s0360-3016(01)01635-2. Int J Radiat Oncol Biol Phys. 2001. PMID: 11483349
-
Inter-observer variations of the tumor bed delineation for patients after breast conserving surgery in preoperative magnetic resonance and computed tomography scan fusion.BMC Cancer. 2021 Jul 20;21(1):838. doi: 10.1186/s12885-021-08546-5. BMC Cancer. 2021. PMID: 34284752 Free PMC article.
-
Variability among breast radiation oncologists in delineation of the postsurgical lumpectomy cavity.Int J Radiat Oncol Biol Phys. 2007 Apr 1;67(5):1299-308. doi: 10.1016/j.ijrobp.2006.11.026. Epub 2007 Feb 1. Int J Radiat Oncol Biol Phys. 2007. PMID: 17275202
-
Current status of PET/CT for tumour volume definition in radiotherapy treatment planning for non-small cell lung cancer (NSCLC).Lung Cancer. 2007 Aug;57(2):125-34. doi: 10.1016/j.lungcan.2007.03.020. Epub 2007 May 2. Lung Cancer. 2007. PMID: 17478008 Review.
-
Delineation of target volumes and organs at risk in adjuvant radiotherapy of early breast cancer: national guidelines and contouring atlas by the Danish Breast Cancer Cooperative Group.Acta Oncol. 2013 May;52(4):703-10. doi: 10.3109/0284186X.2013.765064. Epub 2013 Feb 19. Acta Oncol. 2013. PMID: 23421926
Cited by
-
Inter-observer variability of clinical target volume delineation in definitive radiotherapy of neck lymph node metastases from unknown primary. A cooperative study of the Italian Association of Radiotherapy and Clinical Oncology (AIRO) Head and Neck Group.Radiol Med. 2019 Jul;124(7):682-692. doi: 10.1007/s11547-019-01006-y. Epub 2019 Mar 9. Radiol Med. 2019. PMID: 30852793
-
Geometric contour variation in clinical target volume of axillary lymph nodes in breast cancer radiotherapy: an AIRO multi-institutional study.Br J Radiol. 2021 Jul 1;94(1123):20201177. doi: 10.1259/bjr.20201177. Epub 2021 Apr 21. Br J Radiol. 2021. PMID: 33882239 Free PMC article.
-
Does ultrasound provide any added value in breast contouring for radiotherapy after conserving surgery for cancer?Radiat Oncol. 2015 Aug 22;10:179. doi: 10.1186/s13014-015-0487-4. Radiat Oncol. 2015. PMID: 26296659 Free PMC article.
-
Deep learning-assisted interactive contouring of lung cancer: Impact on contouring time and consistency.Radiother Oncol. 2024 Nov;200:110500. doi: 10.1016/j.radonc.2024.110500. Epub 2024 Sep 3. Radiother Oncol. 2024. PMID: 39236985 Free PMC article.
-
Intensity-modulated radiation therapy using TomoDirect for postoperative radiation of left-sided breast cancer including lymph node area: comparison with TomoHelical and three-dimensional conformal radiation therapy.J Radiat Res. 2019 Oct 23;60(5):694-704. doi: 10.1093/jrr/rrz052. J Radiat Res. 2019. PMID: 31365118 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical