Bacterial contamination of human organ-cultured corneas
- PMID: 11322413
- DOI: 10.1097/00003226-200104000-00005
Bacterial contamination of human organ-cultured corneas
Abstract
Purpose: The aim of this study was to detect and identify bacterial contaminants in human corneoscleral tissue after organ culture storage.
Methods: Seventy-two corneoscleral rims and corneal buttons trephined from organ cultured corneoscleral discs using aseptic technique and 45 organ-cultured donor corneoscleral rims postpenetrating keratoplasty) were subjected to a mechanical extraction technique using a Stomacher laboratory blender. As a control, 28 of the corneoscleral rims and buttons were halved; one half of each corneoscleral rim and button was decontaminated in formalin for 48 hours before thorough washing in balanced salt solution. Corneal specimens, culture medium, and transport (5% dextran) medium were cultured in brain-heart infusion broth at 37 degrees C for 5 days. Bacterial isolates were identified after culture of turbid enrichment broth.
Results: Bacterial contamination was demonstrated in 29% (21 of 72) of the corneoscleral rims and 15% (11 of 72) of the corneal buttons that were trephined aseptically from corneoscleral discs and in 29% (13 of 45) of postkeratoplasty corneoscleral rims. Bacterial contaminants were not isolated from controls. Isolated microorganisms included coagulase-negative Staphylococcus, Staphylococcus aureus, Streptococcus viridans, Pseudomonas sp, and Bacillus sp. A correlation was not demonstrated between contamination and cause of death, death to enucleation, death to culture time, or time in culture. Postkeratoplasty endophthalmitis was not evident in the patients who had received corneal buttons from those corneoscleral discs that had contaminated corneoscleral rims.
Conclusions: Bacterial contamination exists in corneoscleral tissue after organ culture storage. The difference in distribution of bacteria and percentage of contamination between the peripheral and central corneas causes us to question the value of routine postpenetrating keratoplasty corneoscleral rim cultures.
Similar articles
-
Corneoscleral rim cultures: lack of utility and implications for clinical decision-making and infection prevention in the care of patients undergoing corneal transplantation.Cornea. 2001 Aug;20(6):586-9. doi: 10.1097/00003226-200108000-00006. Cornea. 2001. PMID: 11473157
-
The prevalence and risk factors for donor corneal button contamination and its association with ocular infection after transplantation.Cornea. 2004 Oct;23(7):649-54. doi: 10.1097/01.ico.0000139633.50035.cf. Cornea. 2004. PMID: 15448488
-
Is microbiological analysis of donor cornea transport culture media necessary?Eur J Ophthalmol. 2009 Jan-Feb;19(1):137-8. doi: 10.1177/112067210901900121. Eur J Ophthalmol. 2009. PMID: 19123162
-
The prognostic role of donor corneoscleral rim cultures in corneal transplantation.Ophthalmology. 2007 Mar;114(3):440-5. doi: 10.1016/j.ophtha.2006.09.006. Ophthalmology. 2007. PMID: 17324694
-
Donor cornea bacterial contamination.Cornea. 1991 Sep;10(5):381-6. doi: 10.1097/00003226-199109000-00004. Cornea. 1991. PMID: 1935134 Review.
Cited by
-
Validation of Microbiological Testing of Tissue Preparations with Different Incubation Temperatures.Transfus Med Hemother. 2021 Feb;48(1):23-31. doi: 10.1159/000513646. Epub 2020 Dec 16. Transfus Med Hemother. 2021. PMID: 33708049 Free PMC article.
-
Killing efficacy of a new hypothermic corneal storage medium against the micro-organisms frequently found in human donor cornea intended for transplantation.BMJ Open Ophthalmol. 2021 Dec 17;6(1):e000833. doi: 10.1136/bmjophth-2021-000833. eCollection 2021. BMJ Open Ophthalmol. 2021. PMID: 34988292 Free PMC article.
-
Evaluation of the HB&L System for the Microbiological Screening of Storage Medium for Organ-Cultured Corneas.J Ophthalmol. 2013;2013:670947. doi: 10.1155/2013/670947. Epub 2013 Aug 28. J Ophthalmol. 2013. PMID: 24069532 Free PMC article.
-
Heart valves should not be routinely cultured.J Clin Microbiol. 2008 Sep;46(9):2897-901. doi: 10.1128/JCM.02173-07. Epub 2008 Jul 16. J Clin Microbiol. 2008. PMID: 18632908 Free PMC article.
-
Next-generation sequencing for the detection of microorganisms present in human donor corneal preservation medium.BMJ Open Ophthalmol. 2019 Apr 20;4(1):e000246. doi: 10.1136/bmjophth-2018-000246. eCollection 2019. BMJ Open Ophthalmol. 2019. PMID: 31179394 Free PMC article.