Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2001 May;45(5):770-80.
doi: 10.1002/mrm.1105.

Analysis of partial volume effects in diffusion-tensor MRI

Affiliations
Free article

Analysis of partial volume effects in diffusion-tensor MRI

A L Alexander et al. Magn Reson Med. 2001 May.
Free article

Abstract

The diffusion tensor is currently the accepted model of diffusion in biological tissues. The measured diffusion behavior may be more complex when two or more distinct tissues with different diffusion tensors occupy the same voxel. In this study, a partial volume model of MRI signal behavior for two diffusion-tensor compartments is presented. Simulations using this model demonstrate that the conventional single diffusion tensor model could lead to highly variable and inaccurate measurements of diffusion behavior. The differences between the single and two-tensor models depend on the orientations, fractions, and exchange between the two diffusion tensor compartments, as well as the diffusion-tensor encoding technique and diffusion-weighting that is used in the measurements. The current single compartment model's inaccuracies could cause diffusion-based characterization of cerebral ischemia and white matter connectivity to be incorrect. A diffusion-tensor MRI imaging experiment on a normal human brain revealed significant partial volume effects between oblique white matter regions when using very large voxels and large diffusion-weighting (b approximately 2.69 x 10(3) sec/mm(2)). However, the apparent partial volume effects in white matter decreased significantly when smaller voxel dimensions were used. For diffusion tensor studies obtained using typical diffusion-weighting values (b approximately 1 x 10(3) sec/mm(2)) partial volume effects are much more difficult to detect and resolve. More accurate measurements of multiple diffusion compartments may lead to improved confidence in diffusion measurements for clinical applications.

PubMed Disclaimer

Publication types

LinkOut - more resources