Measurement of thermal conductivity of bovine cortical bone
- PMID: 11334760
- DOI: 10.1016/s1350-4533(01)00003-0
Measurement of thermal conductivity of bovine cortical bone
Abstract
The thermal conductivity of cortical bone was characterized experimentally. Specimens were taken from the mid-diaphysis of bovine femora, and the rate of heat transfer was measured in three orthogonal directions. The conductivity was found to be 0.58+/-0.018 W/mK in the longitudinal direction, 0.53+/-0.030 W/mK in the circumferential direction, and 0.54+/-0.020 W/mK in the radial direction. Because the directional differences are small, it is concluded that bovine cortical bone can be treated as thermally isotropic.
Similar articles
-
A study of dielectric anisotropy in dehydrated cortical bone.Med Prog Technol. 1995-1996;21(3):165-70. Med Prog Technol. 1995. PMID: 8776713
-
The thermal conductivity of cortical and cancellous bone.Eur Cell Mater. 2018 Jan 28;35:25-33. doi: 10.22203/eCM.v035a03. Eur Cell Mater. 2018. PMID: 29376217
-
Thermal properties of cancellous bone.J Biomed Mater Res. 1975 Mar;9(2):169-82. doi: 10.1002/jbm.820090206. J Biomed Mater Res. 1975. PMID: 1176477
-
Temperature rise during drilling through bone.Int J Oral Maxillofac Implants. 1997 May-Jun;12(3):342-53. Int J Oral Maxillofac Implants. 1997. PMID: 9197099 Review.
-
The elastic anisotropy of bone.J Biomech. 1987;20(11-12):1063-70. doi: 10.1016/0021-9290(87)90024-8. J Biomech. 1987. PMID: 3323198 Review.
Cited by
-
Thermal model to investigate the temperature in bone grinding for skull base neurosurgery.Med Eng Phys. 2013 Oct;35(10):1391-8. doi: 10.1016/j.medengphy.2013.03.023. Epub 2013 May 15. Med Eng Phys. 2013. PMID: 23683875 Free PMC article.
-
Thermal changes during implant site preparation with a digital surgical guide and slot design drill: an ex vivo study using a bovine rib model.J Periodontal Implant Sci. 2022 Oct;52(5):411-421. doi: 10.5051/jpis.2106040302. J Periodontal Implant Sci. 2022. PMID: 36302647 Free PMC article.
-
Non-Destructive Removal of Dental Implant by Using the Cryogenic Method.Medicina (Kaunas). 2022 Jun 25;58(7):849. doi: 10.3390/medicina58070849. Medicina (Kaunas). 2022. PMID: 35888569 Free PMC article.
-
The influence of the chosen in vitro bone simulation model on intraosseous temperatures and drilling times.Sci Rep. 2019 Aug 14;9(1):11817. doi: 10.1038/s41598-019-48416-6. Sci Rep. 2019. PMID: 31413292 Free PMC article.
-
The apparent critical isotherm for cryoinsult-induced osteonecrotic lesions in emu femoral heads.J Biomech. 2008 Jul 19;41(10):2197-205. doi: 10.1016/j.jbiomech.2008.04.032. Epub 2008 Jun 17. J Biomech. 2008. PMID: 18561937 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources