Reproducibility of ductus venosus Doppler flow measurements at 11-14 weeks of gestation
- PMID: 11339185
- DOI: 10.1046/j.1469-0705.2001.00338.x
Reproducibility of ductus venosus Doppler flow measurements at 11-14 weeks of gestation
Abstract
Objectives: To assess the intra- and interobserver repeatabilities of fetal ductus venosus Doppler measurements at 11-14 weeks of gestation.
Design: Flow velocity waveforms were recorded transabdominally. Intraobserver repeatability was studied in 22 fetuses in whom four repeated measurements were performed by the same observer. Interobserver repeatability was assessed in 54 fetuses in each of whom two observers performed two repeated measurements. The pulsatility index for veins (PIV), peak velocity during ventricular systole (S wave), peak velocity during atrial contraction (A wave) and time-averaged maximum velocity (TAMV) were recorded. Reproducibility of the Doppler measurements was analyzed by calculating repeatability coefficient, coefficient of variation (CV), intraclass correlation coefficient (ICC), mean differences and their limits of agreement. Cohen's k-coefficient was used for categorical data.
Results: Intraobserver repeatability was good with a CV of 10%, 13%, 22% and 13% and an ICC of 0.85, 0.94, 0.94 and 0.95, respectively, for PIV, S wave, A wave and TAMV. Interobserver repeatability was also good, and no bias between the observers was detected. A CV of 8.8%, 14%, 27% and 15% and an ICC of 0.86, 0.84, 0.87 and 0.84, respectively, for PIV, S wave, A wave and TAMV were obtained. There was 100% agreement for the detection of normal/abnormal blood flow.
Conclusions: Intra- and interobserver repeatability of all parameters was acceptable, allowing for the detection of moderate to large changes in Doppler measurements.
Similar articles
-
Intraobserver and interobserver variability of transabdominal Doppler velocimetry measurements of the fetal ductus venosus between 10 and 14 weeks of gestation.Ultrasound Obstet Gynecol. 2001 Apr;17(4):306-10. doi: 10.1046/j.1469-0705.2001.00386.x. Ultrasound Obstet Gynecol. 2001. PMID: 11339186
-
Reproducibility of transvaginal Doppler velocimetry measurements in the uterine arteries of postmenopausal women.Ultrasound Obstet Gynecol. 1997 Sep;10(3):198-204. doi: 10.1046/j.1469-0705.1997.10030198.x. Ultrasound Obstet Gynecol. 1997. PMID: 9339527 Clinical Trial.
-
Reference values for ductus venosus Doppler flow measurements at 10-14 weeks of gestation.Ultrasound Obstet Gynecol. 2002 Jul;20(1):42-6. doi: 10.1046/j.1469-0705.2002.00710.x. Ultrasound Obstet Gynecol. 2002. PMID: 12100416
-
Effect of fetal gender on first-trimester ductus venosus blood flow.Ultrasound Obstet Gynecol. 2003 Sep;22(3):268-70. doi: 10.1002/uog.205. Ultrasound Obstet Gynecol. 2003. PMID: 12942499
-
The controversial role of the ductus venosus in hypoxic human fetuses.Acta Obstet Gynecol Scand. 2019 Jul;98(7):823-829. doi: 10.1111/aogs.13572. Epub 2019 Apr 23. Acta Obstet Gynecol Scand. 2019. PMID: 30742329 Review.
Cited by
-
Reproducibility and repeatability of measuring the electrical impedance of the pregnant human cervix-the effect of probe size and applied pressure.Biomed Eng Online. 2009 Jun 17;8:10. doi: 10.1186/1475-925X-8-10. Biomed Eng Online. 2009. PMID: 19534806 Free PMC article.
-
Doppler assessment of the ductus venosus and the tricuspid valve at 11-13+6 weeks: Reference ranges and development of sonographic quality assurance standards.Australas J Ultrasound Med. 2016 Feb 21;19(1):30-36. doi: 10.1002/ajum.12000. eCollection 2016 Feb. Australas J Ultrasound Med. 2016. PMID: 34760440 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources