A theoretical derivation of the nomograms for permanent prostate brachytherapy
Abstract
This study calculates the required minimum radioactivity to deliver a prescribed dose of radiation to a target using radioisotopes in permanent prostate brachytherapy. Assuming the radioactivity to be in a continuous form, an integral equation--Fredholm equation of the first kind, can be formulated with the radioactivity density used as the variable. The density distribution to produce a uniform volume dose rate is determined using a quadrature method and the radial profile behaves smoothly from the zero radius, and peaks sharply approaching the volume boundary. The density for Pd-103 is about 1.5 times that of I-125 due to its higher spatial attenuation. A nomogram is the relationship between the total activity per unit dose (A) and the dimension of the volume (d). Expressing the nomogram as A=c X dn U/Gy, then (c,n)= [(0.0098, 2.09) I-125] and [(0.031, 2.25) Pd-103]. Compared with the Memorial nomogram, (c,n)=[(0.011,2.2) I-125] and [(0.036,2.56) Pd-103], or that quoted by AAPM TG64, (c,n)=[(0.014,2.05) I-125] and [(0.056,2.22) Pd-103], our calculation determined an average 33% and 35% decrease for I-125, and 89% and 77% decrease for Pd-103, respectively. Two reasons for the extra total activity found in the Memorial and AAPM nomograms are: (a) An imperfect clinical situation limited by the restraints of implant techniques (e.g., use of templates) associated with the presence of adjacent normal organs, and (b) source discretization into seeds. When radioactivity is clumped as discrete seeds, higher activity is needed because of "wastage" in two aspects: (a) Dose cold-spots at intersource spaces, (b) hot-spots around the sources. Thus in theory, use of lower activity seeds will require less total activity to deliver a prescribed dose. Based on our study, Pd-103 delivers a higher therapeutic ratio and a lower integral dose to the patient compared to I-125.
Similar articles
-
Reducing seed waste and increasing value of dynamic intraoperative implantation of Pd-103 seeds in prostate brachytherapy.J Appl Clin Med Phys. 2018 Sep;19(5):383-388. doi: 10.1002/acm2.12404. Epub 2018 Jul 13. J Appl Clin Med Phys. 2018. PMID: 30003681 Free PMC article.
-
The effect of seed anisotrophy on brachytherapy dose distributions using 125I and 103Pd.Med Phys. 2001 Mar;28(3):336-45. doi: 10.1118/1.1350674. Med Phys. 2001. PMID: 11318315
-
Intraoperative fluoroscopic dose assessment in prostate brachytherapy patients.Int J Radiat Oncol Biol Phys. 2005 Sep 1;63(1):301-7. doi: 10.1016/j.ijrobp.2005.05.039. Int J Radiat Oncol Biol Phys. 2005. PMID: 16111600 Clinical Trial.
-
Recommendations of the American Association of Physicists in Medicine regarding the impact of implementing the 2004 task group 43 report on dose specification for 103Pd and 125I interstitial brachytherapy.Med Phys. 2005 May;32(5):1424-39. doi: 10.1118/1.1884925. Med Phys. 2005. PMID: 15984693 Review.
-
The impact of technological advances on the evolution of 3D conformal brachytherapy for early prostate cancer.Technol Cancer Res Treat. 2004 Aug;3(4):335-45. doi: 10.1177/153303460400300403. Technol Cancer Res Treat. 2004. PMID: 15270584 Review.
Cited by
-
A simple technique for the generation of institution-specific nomograms for permanent prostate cancer brachytherapy.J Contemp Brachytherapy. 2014 Oct;6(3):293-6. doi: 10.5114/jcb.2014.45582. Epub 2014 Sep 23. J Contemp Brachytherapy. 2014. PMID: 25337132 Free PMC article.
-
Reducing seed waste and increasing value of dynamic intraoperative implantation of Pd-103 seeds in prostate brachytherapy.J Appl Clin Med Phys. 2018 Sep;19(5):383-388. doi: 10.1002/acm2.12404. Epub 2018 Jul 13. J Appl Clin Med Phys. 2018. PMID: 30003681 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical