Dynamic computed tomography study of the brain
- PMID: 113434
- DOI: 10.1097/00004728-197910000-00013
Dynamic computed tomography study of the brain
Abstract
The dynamic computed tomography (CT) study of the brain consists of the rapid intravenous injection of 49 ml of radiographic contrast material in 7 sec followed by serial 5 sec CT scans with interscan times of only 1 sec. The data from these scans can be reprocessed to create 12 segmented images in 35 sec. When small samples of four to six pixels of cortex are examined by the cursor, sharp rises of 20 to 25 CT units (500 scale) are seen on the time--density curves. Samples of white matter are usually no more than 2 CT units. When larger cursor samples of 220 to 255 pixels including cortex and white matter are examined, the time--density curves represent a combination of these two patterns. Comparison between symmetrical areas in the two hemispheres generally shows parallel curves in controls. The studies provide high resolution cerebral perfusion images. In ischemia secondary to ipsilateral carotid stenosis, there is depression of the up-slope and a depressed and late peak. Infarctions show a flat perfusion curve. Several patterns in brain tumors are illustrated. The study, simple to perform, adds significant perfusion information to the previously static CT examination of the brain.
Similar articles
-
Dynamic computed tomography study of the brain.Adv Neurol. 1981;30:85-95. Adv Neurol. 1981. PMID: 6272558
-
Patterns of brain perfusion: dynamic computed tomography using intravenous contrast enhancement.J Comput Assist Tomogr. 1979 Oct;3(5):633-40. J Comput Assist Tomogr. 1979. PMID: 113433
-
Dynamic hepatic CT: uniphasic and biphasic contrast medium injection protocols.Ann Univ Mariae Curie Sklodowska Med. 1999;54:195-204. Ann Univ Mariae Curie Sklodowska Med. 1999. PMID: 11205764 Clinical Trial. No abstract available.
-
Dynamic CT using an arterial bolus.Radiology. 1985 Nov;157(2):529-30. doi: 10.1148/radiology.157.2.4048463. Radiology. 1985. PMID: 4048463
-
[Contrast enhancement].Pol Przegl Radiol Med Nukl. 1982 Jul-Aug;46(4):179-86. Pol Przegl Radiol Med Nukl. 1982. PMID: 6763211 Review. Polish. No abstract available.
Cited by
-
Cerebral peak time mapping uniformity of the value of peak time.Neuroradiology. 1987;29(2):160-2. doi: 10.1007/BF00327541. Neuroradiology. 1987. PMID: 3587590
-
Dynamic computed tomography of the brain.Neurosurg Rev. 1985;8(1):15-25. doi: 10.1007/BF01744874. Neurosurg Rev. 1985. PMID: 4022396
-
Neurological improvement after cranioplasty. Analysis by dynamic CT scan.Acta Neurochir (Wien). 1993;122(1-2):49-53. doi: 10.1007/BF01446986. Acta Neurochir (Wien). 1993. PMID: 8333309
-
Bilateral aneurysms of the juxtasellar segment of the internal carotid artery.Acta Neurochir (Wien). 1981;57(3-4):235-45. doi: 10.1007/BF01664840. Acta Neurochir (Wien). 1981. PMID: 7282445 No abstract available.
-
CT perfusion: technical developments and current and future applications.Biomed Res Int. 2015;2015:397521. doi: 10.1155/2015/397521. Epub 2015 Jan 28. Biomed Res Int. 2015. PMID: 25695071 Free PMC article. No abstract available.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources