Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2001 May;88(5):653-61.
doi: 10.1046/j.1365-2168.2001.01768.x.

Cost-utility analysis of open versus laparoscopic groin hernia repair: results from a multicentre randomized clinical trial

Clinical Trial

Cost-utility analysis of open versus laparoscopic groin hernia repair: results from a multicentre randomized clinical trial

Medical Research Council Laparoscopic Groin Hernia Trial Group.. Br J Surg. 2001 May.

Abstract

Background: This study was a pragmatic economic evaluation carried out alongside a multicentre randomized controlled trial comparing laparoscopic with open groin hernia repair. The primary economic evaluation framework employed was a cost-utility analysis.

Methods: At 26 hospitals in the UK and Ireland, 928 patients with a groin hernia were assigned randomly to laparoscopic or open repair. Cost data were identified and measured both within and outwith the trial. Cost data were combined with quality-adjusted life years (QALYs) from the EQ-5D questionnaire to obtain cost-per-QALY ratios.

Results: The mean cost of laparoscopic hernia repair was pound1112.64, compared with pound788.79 for the open operation. The extra cost of pound323.85 in the laparoscopic group was mainly due to additional theatre time and increased equipment and sterilization costs. The estimated incremental cost per QALY of the laparoscopic over the open method was pound55 548.00 (95 per cent confidence interval pound47 216.00- pound63 885.00).

Conclusion: While the results show that a high cost was incurred to produce an additional QALY by using laparoscopic over open hernia repair, sensitivity analyses show that there are specific situations in which laparoscopic repair may be a viable alternative, such as when reusable equipment is employed.