Dielectric resonances and B(1) field inhomogeneity in UHFMRI: computational analysis and experimental findings
- PMID: 11358660
- DOI: 10.1016/s0730-725x(01)00300-9
Dielectric resonances and B(1) field inhomogeneity in UHFMRI: computational analysis and experimental findings
Abstract
B(1) Field inhomogeneity and the relative effects of dielectric resonances are analyzed within the context of ultra high field MRI. This is accomplished by calculating the electromagnetic fields inside spherical phantoms and within a human head model in the presence and absence of an RF coil. These calculations are then compared to gradient echo and RARE images, respectively. For the spherical phantoms, plane incident wave analyses are initially presented followed by full wave finite difference time domain (FDTD) calculations. The FDTD methods are then utilized to examine the electromagnetic interactions between the TEM resonator and an anatomically detailed human head model. The results at 340 MHz reveal that dielectric resonances are most strongly excited in objects similar in size to the human head when the conducting medium has a high dielectric constant and a low conductivity. It is concluded that in clinical UFHMRI, the most important determinants of B(1) field homogeneity consist of 1) the RF coil design, 2) the interaction between the RF coil, the excitation source and the sample, and finally 3) the geometry and electrical properties of the sample.
Similar articles
-
Black body and transverse electromagnetic resonators operating at 340 MHz: volume RF coils for ultra high field MRI.J Comput Assist Tomogr. 1999 Nov-Dec;23(6):879-90. doi: 10.1097/00004728-199911000-00011. J Comput Assist Tomogr. 1999. PMID: 10589562
-
Dielectric resonance phenomena in ultra high field MRI.J Comput Assist Tomogr. 1999 Nov-Dec;23(6):821-31. doi: 10.1097/00004728-199911000-00003. J Comput Assist Tomogr. 1999. PMID: 10589554
-
A spiral volume coil for improved RF field homogeneity at high static magnetic field strength.Magn Reson Med. 1998 Jul;40(1):49-54. doi: 10.1002/mrm.1910400107. Magn Reson Med. 1998. PMID: 9660552
-
[Clinical high- and ultrahigh-field MR and its interaction with biological systems].Radiologe. 2004 Jan;44(1):19-30. doi: 10.1007/s00117-003-0993-5. Radiologe. 2004. PMID: 14740093 Review. German.
-
Numerical field calculations considering the human subject for engineering and safety assurance in MRI.NMR Biomed. 2009 Nov;22(9):919-26. doi: 10.1002/nbm.1251. NMR Biomed. 2009. PMID: 18384179 Free PMC article. Review.
Cited by
-
From strength to precision: A systematic review exploring the clinical utility of 7-Tesla magnetic resonance imaging in abdominal imaging.World J Radiol. 2024 Jan 28;16(1):20-31. doi: 10.4329/wjr.v16.i1.20. World J Radiol. 2024. PMID: 38312348 Free PMC article.
-
Unsupervised deep learning with convolutional neural networks for static parallel transmit design: A retrospective study.Magn Reson Med. 2024 Jun;91(6):2498-2507. doi: 10.1002/mrm.30014. Epub 2024 Jan 21. Magn Reson Med. 2024. PMID: 38247050 Free PMC article.
-
RF pulse methods for use with surface coils: Frequency-modulated pulses and parallel transmission.J Magn Reson. 2018 Jun;291:84-93. doi: 10.1016/j.jmr.2018.01.012. Epub 2018 Apr 26. J Magn Reson. 2018. PMID: 29705035 Free PMC article. Review.
-
Hybrid-pair ratio adjustable power splitters for add-on RF shimming and array-compressed parallel transmission.Magn Reson Med. 2021 Dec;86(6):3382-3390. doi: 10.1002/mrm.28934. Epub 2021 Jul 19. Magn Reson Med. 2021. PMID: 34286860 Free PMC article.
-
High-resolution imaging of the excised porcine heart at a whole-body 7 T MRI system using an 8Tx/16Rx pTx coil.MAGMA. 2023 Apr;36(2):279-293. doi: 10.1007/s10334-023-01077-z. Epub 2023 Apr 7. MAGMA. 2023. PMID: 37027119 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical