Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2001 May;132(5):639-45.
doi: 10.14219/jada.archive.2001.0241.

The suitability of packable resin-based composites for posterior restorations

Affiliations

The suitability of packable resin-based composites for posterior restorations

J Manhart et al. J Am Dent Assoc. 2001 May.

Abstract

Background: Packable composites, promoted for the restoration of stress-bearing posterior teeth, have captured clinicians' interest.

Methods: The authors tested three packable composites (Alert, Jeneric/Pentron; Solitaire, Heraeus Kulzer, Wehrheim, Germany; SureFil, Dentsply De Trey, Konstanz, Germany); a new packable organically modified ceramic, or ormocer (Definite, Degussa AG, Hanau, Germany); a hybrid composite (Tetric Ceram, Ivoclar Vivadent, Schaan, Liechtenstein) and an ion-releasing composite (Ariston pHc, Ivoclar Vivadent, Schaan, Liechtenstein). They determined modulus of elasticity according to EN 24049:1993 of the European Committee for Standardization. They measured Vickers hardness using a 200-gram load for 40 seconds. To determine the materials' depth of cure, they used both a scraping method (International Standards Organization standard CD 4049:1997) and a hardness profiling method.

Results: The authors calculated means and standard deviations from 10 replications of each test and used one-way analysis of variance and post hoc Tukey tests (alpha = .05). The materials had significant differences (P < .001) in all characteristics. Solitaire had the significantly lowest elastic modulus and microhardness; Alert had the highest values for these characteristics. Ariston pHc exhibited the significantly lowest depth of cure. There was a significant correlation between the two methods of measuring depth of cure (r2 = 0.9945; P = .021).

Conclusions: The material group of packable composites is rather inhomogeneous in terms of mechanical and physical data. Our data suggest that bulk curing of packable composites in deep cavities still is not recommendable.

Clinical implications: The clinician needs to select packable composites carefully, as it seems that not all of these materials quality for stress-loaded posterior restorations.

PubMed Disclaimer

LinkOut - more resources