Validation of STR typing by capillary electrophoresis
Abstract
With the use of capillary electrophoresis (CE), high-resolution electrophoretic separation of short tandem repeat (STR) loci can be achieved in a semiautomated fashion. Laser-induced detection of fluorescently labeled PCR products and multicolor analysis enable the rapid generation of multilocus DNA profiles. In this study, conditions for typing PCR-amplified STR loci by capillary electrophoresis were investigated using the ABI Prism 310 Genetic Analyzer (Applied Biosystems). An internal size standard was used with each run to effectively normalize mobility differences among injections. Alleles were designated by comparison to allelic ladders that were run with each sample set. Multiple runs of allelic ladders and of amplified samples demonstrate that allele sizes were reproducible, with standard deviations typically less than 0.12 bases for fragments up to 317 bases in length (largest allele analyzed) separated in a 47 cm capillary. Therefore, 99.7% of all alleles that are the same length should fall within the measurement error window of +/- 0.36 bases. Microvariants of the tetranucleotide repeats were also accurately typed by the analytical software. Alleles differing in size by one base could be resolved in two-donor DNA mixtures in which the minor component comprised > or = 5% of the total DNA. Furthermore, the quantitative data format (i.e., peak amplitude) can in some instances assist in determining individual STR profiles in mixed samples. DNA samples from previously typed cases (typed for RFLP, AmpliType PM+DQA1, and/or D1S80) were amplified using AmpFlSTR Profiler Plus and COfiler and were evaluated using the ABI Prism 310. Most samples yielded typable results. Compared with previously determined results for other loci, there were no discrepancies as to the inclusion or exclusion of suspects or victims. CE thus provides efficient separation, resolution, sensitivity and precision, and the analytical software provides reliable genotyping of STR loci. The analytical conditions described are suitable for typing samples such as reference and evidentiary samples from forensic casework.
Similar articles
-
Validation of short tandem repeats (STRs) for forensic usage: performance testing of fluorescent multiplex STR systems and analysis of authentic and simulated forensic samples.J Forensic Sci. 2001 May;46(3):647-60. J Forensic Sci. 2001. PMID: 11373004
-
Performance evaluation of two multiplexes used in fluorescent short tandem repeat DNA analysis.J Forensic Sci. 2003 Mar;48(2):348-57. J Forensic Sci. 2003. PMID: 12664993
-
Genotyping of forensic short tandem repeat (STR) systems based on sizing precision in a capillary electrophoresis instrument.Electrophoresis. 1998 Jan;19(1):86-93. doi: 10.1002/elps.1150190116. Electrophoresis. 1998. PMID: 9511868
-
Forensic DNA typing by capillary electrophoresis using the ABI Prism 310 and 3100 genetic analyzers for STR analysis.Electrophoresis. 2004 Jun;25(10-11):1397-412. doi: 10.1002/elps.200305822. Electrophoresis. 2004. PMID: 15188225 Review.
-
[The unusual typing of short tandem repeats].Fa Yi Xue Za Zhi. 2002 May;18(2):118-20, 123. Fa Yi Xue Za Zhi. 2002. PMID: 12596600 Review. Chinese.
Cited by
-
Evaluation of forensic DNA mixture evidence: protocol for evaluation, interpretation, and statistical calculations using the combined probability of inclusion.BMC Genet. 2016 Aug 31;17(1):125. doi: 10.1186/s12863-016-0429-7. BMC Genet. 2016. PMID: 27580588 Free PMC article.
-
Magnitude-dependent variation in peak height balance at heterozygous STR loci.Int J Legal Med. 2011 Jan;125(1):87-94. doi: 10.1007/s00414-009-0411-2. Epub 2010 Feb 10. Int J Legal Med. 2011. PMID: 20145943
-
Validity of low copy number typing and applications to forensic science.Croat Med J. 2009 Jun;50(3):207-17. doi: 10.3325/cmj.2009.50.207. Croat Med J. 2009. PMID: 19480017 Free PMC article. Review.
-
Validation of the PowerPlex®35GY System: a novel eight-dye STR multiplex kit on the Spectrum Compact CE System.Int J Legal Med. 2024 Nov;138(6):2299-2314. doi: 10.1007/s00414-024-03308-x. Epub 2024 Aug 13. Int J Legal Med. 2024. PMID: 39134883
-
Fifteen non-CODIS autosomal short tandem repeat loci multiplex data from nine population groups living in Taiwan.Int J Legal Med. 2012 Jul;126(4):671-5. doi: 10.1007/s00414-012-0691-9. Epub 2012 Mar 20. Int J Legal Med. 2012. PMID: 22430197
Publication types
MeSH terms
LinkOut - more resources
Other Literature Sources
Research Materials