Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2001 May 15;44(6):588-613.
doi: 10.1080/00140130118050.

Comparison of self-report, video observation and direct measurement methods for upper extremity musculoskeletal disorder physical risk factors

Affiliations
Comparative Study

Comparison of self-report, video observation and direct measurement methods for upper extremity musculoskeletal disorder physical risk factors

P Spielholz et al. Ergonomics. .

Abstract

The prevention of work-related musculoskeletal disorders has become a national priority in many countries. Increasingly, attempts are made to quantify those exposures that increase risk in order to set exposure limit values. This study used commonly employed field measurement methods and tools in order to perform an inter-method comparison between three primary methods of risk factor exposure assessment: self-report questionnaires, observational video analysis and direct measurement. Extreme posture duration, repetition, hand force (estimated from electromyography) and movement velocity were assessed for 18 subjects while performing each of three jobs processing tree seedlings. Results indicated that self-reports were the least precise assessment method, which consistently overestimated exposures for each of the measured risk factors. However, adjustment of the reports as psychophysical scales may increase agreement on a group level. Wrist flexion/extension duration and repetition were best measured by electrogoniometer. Electrogoniometric measures of wrist deviation duration and frequency were less precise than video analysis. Forearm rotation duration and repetition, grip force and velocity appeared to be best quantified by direct measurement as measured by electrogoniometer and electromyography (EMG) (as root-mean-square amplitude). The results highlight the fact that it is as important to consider and report estimated measurement error in order to reduce potential exposure misclassification in epidemiologic studies.

PubMed Disclaimer

Publication types

LinkOut - more resources