Improvement of the bone-pin interface strength in osteoporotic bone with use of hydroxyapatite-coated tapered external-fixation pins. A prospective, randomized clinical study of wrist fractures
- PMID: 11379741
- DOI: 10.2106/00004623-200105000-00010
Improvement of the bone-pin interface strength in osteoporotic bone with use of hydroxyapatite-coated tapered external-fixation pins. A prospective, randomized clinical study of wrist fractures
Abstract
Background: Achieving adequate fixation strength in osteoporotic bone is a challenge. In this study, we examined the use of hydroxyapatite-coated tapered external-fixation pins for the fixation of wrist fractures in patients with osteoporosis.
Methods: Twenty female patients with osteoporosis and a fracture of the wrist were divided into two paired groups and randomized to receive either standard tapered pins or hydroxyapatite-coated tapered pins. Two pins were inserted in the distal part of the radius, two pins were inserted in the second metacarpal, and an external fixation device was mounted. All fixation devices were removed six weeks after surgery.
Results: The mean pin-insertion torque (and standard deviation) was 461 +/- 254 Nmm in the group managed with standard pins and 332 +/- 176 Nmm in the group managed with hydroxyapatite-coated pins (p = 0.01). The mean pin-extraction torque was 191 +/- 155 Nmm in the group managed with standard pins and 600 +/- 214 Nmm in the group managed with hydroxyapatite-coated pins (p < 0.0001, power 95%). The mean extraction torque was lower than the corresponding insertion torque at each pin position in the group managed with standard pins (p < 0.05), whereas the mean extraction torque was higher than the corresponding insertion torque at each pin position in the group managed with hydroxyapatite-coated pins (p = 0.001). Two patients managed with standard pins and no patient managed with hydroxyapatite-coated pins had a pin-track infection. Pain during pin removal did not differ between the two groups.
Conclusions: The present study showed that hydroxyapatite-coated tapered external-fixation pins provided improved fixation in the treatment of wrist fractures in patients with osteoporosis.
Similar articles
-
Hydroxyapatite-coated external fixation pins.Expert Rev Med Devices. 2005 Jul;2(4):465-71. doi: 10.1586/17434440.2.4.465. Expert Rev Med Devices. 2005. PMID: 16293085 Review.
-
State of the art review: techniques to avoid pin loosening and infection in external fixation.J Orthop Trauma. 2002 Mar;16(3):189-95. doi: 10.1097/00005131-200203000-00009. J Orthop Trauma. 2002. PMID: 11880783 Review.
-
Fixation strength and pin tract infection of hydroxyapatite-coated tapered pins.Clin Orthop Relat Res. 2001 Jul;(388):209-17. doi: 10.1097/00003086-200107000-00029. Clin Orthop Relat Res. 2001. PMID: 11451122 Clinical Trial.
-
Enhanced fixation with hydroxyapatite coated pins.Clin Orthop Relat Res. 1998 Jan;(346):171-7. Clin Orthop Relat Res. 1998. PMID: 9577425 Clinical Trial.
-
Hydroxyapatite-coated pins versus titanium alloy pins in external fixation at the wrist: a controlled cohort study.J Trauma. 2011 Apr;70(4):845-51. doi: 10.1097/TA.0b013e3181e97761. J Trauma. 2011. PMID: 20805762 Clinical Trial.
Cited by
-
Bioinspired polydopamine and polyphenol tannic acid functionalized titanium suppress osteoclast differentiation: a facile and efficient strategy to regulate osteoclast activity at bone-implant interface.J R Soc Interface. 2019 Mar 29;16(152):20180799. doi: 10.1098/rsif.2018.0799. J R Soc Interface. 2019. PMID: 30836894 Free PMC article.
-
Role of coatings and materials of external fixation pins on the rates of pin tract infection: A systematic review and meta-analysis.World J Orthop. 2021 Nov 18;12(11):920-930. doi: 10.5312/wjo.v12.i11.920. eCollection 2021 Nov 18. World J Orthop. 2021. PMID: 34888152 Free PMC article.
-
Comparison of the Dynamic Hip Screw with the Dynamic Hip External Fixator for Intertrochanteric Fractures: Report of a Randomized Controlled Trial.Arch Bone Jt Surg. 2021 Nov;9(6):665-676. doi: 10.22038/ABJS.2021.53705.2672. Arch Bone Jt Surg. 2021. PMID: 35106332 Free PMC article.
-
Chitosan-coated stainless steel screws for fixation in contaminated fractures.Clin Orthop Relat Res. 2008 Jul;466(7):1699-704. doi: 10.1007/s11999-008-0269-5. Epub 2008 Apr 29. Clin Orthop Relat Res. 2008. PMID: 18443893 Free PMC article.
-
Pin site care for preventing infections associated with external bone fixators and pins.Cochrane Database Syst Rev. 2013 Dec 3;2013(12):CD004551. doi: 10.1002/14651858.CD004551.pub3. Cochrane Database Syst Rev. 2013. PMID: 24302374 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical