Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2001 Jun;48(6):660-9.
doi: 10.1109/10.923784.

Localization of the site of origin of cardiac activation by means of a heart-model-based electrocardiographic imaging approach

Affiliations

Localization of the site of origin of cardiac activation by means of a heart-model-based electrocardiographic imaging approach

G Li et al. IEEE Trans Biomed Eng. 2001 Jun.

Abstract

We have developed a new approach to solve the inverse problem of electrocardiography in terms of heart model parameters. The inverse solution of the electrocardiogram (ECG) inverse problem is defined, in the present study, as the parameters of the heart model, which are closely related to the physiological and pathophysiological status of the heart, and is estimated by using an optimization system of heart model parameters, instead of solving the matrix equation relating the body surface ECGs and equivalent cardiac sources. An artificial neural network based preliminary diagnosis system has been developed to limit the searching space of the optimization algorithm and to initialize the model parameters in the computer heart model. The optimal heart model parameters were obtained by minimizing the objective functions, as functions of the observed and model-generated body surface ECGs. We have tested the feasibility of the newly developed technique in localizing the site of origin of cardiac activation using a pace mapping protocol. The present computer simulation results show that, the present approach for localization of the site of origin of ventricular activation achieved an averaged localization error of about 3 mm [for 5-muV Gaussian white noise (GWN)] and 4 mm (for 10-muV GWN), with standard deviation of the localization errors of being about 1.5 mm. The present simulation study suggests that this newly developed approach provides a robust inverse solution, circumventing the difficulties of the ECG inverse problem, and may become an important alternative to other ECG inverse solutions.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources