Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2001 Jun;12(6):716-25.
doi: 10.1016/S1044-0305(01)00241-0.

Protein fluorescence measurements within electrospray droplets

Affiliations
Free article

Protein fluorescence measurements within electrospray droplets

S E Rodriguez-Cruz et al. J Am Soc Mass Spectrom. 2001 Jun.
Free article

Abstract

The conformation of cytochrome c molecules within electrospray droplets is investigated by monitoring the laser induced fluorescence of its single tryptophan residue (Trp-59). By increasing the alcohol concentration of the electrosprayed solutions, protein denaturation is induced, giving rise to significant changes in the intensity of the detected fluorescence. Comparison with analogous denaturation experiments in solution provides information about the relative protein conformations and differences between the bulk-solution and droplet environments. Both electrospray-plume and bulk-solution fluorescence measurements using low methanol concentration solutions indicate the presence of folded protein structures. At high methanol content, fluorescence measurements are consistent with the presence of partly denatured or unfolded conformations. At intermediate methanol content, differences are observed between the extent of denaturation in solution and that within the droplets, suggesting electrosprayed proteins have more compact structures than those detected in bulk measurements using solutions of similar composition. This infers that some fraction of the proteins within the droplets have refolded relative to their bulk-solution conformation. Protein denaturation experiments using the low vapor pressure solvent 1-propanol indicate that differences between the droplet and solution measurements are not due to solvent evaporation effects. It is suggested that different droplet conformations are more likely the result of protein diffusion to the droplet surface and effects of the droplet/air interface. To our knowledge, these are the first reported measurements of protein fluorescence within electrospray droplets.

PubMed Disclaimer

References

    1. Rapid Commun Mass Spectrom. 1990 Mar;4(3):81-7 - PubMed
    1. Anal Chem. 1988 Oct 15;60(20):2299-301 - PubMed
    1. Nature. 1988 Oct 20;335(6192):700-4 - PubMed
    1. Science. 1989 Oct 6;246(4926):64-71 - PubMed
    1. Biochemistry. 1980 Jan 8;19(1):199-207 - PubMed

Publication types

LinkOut - more resources