Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2001 Apr 15;291(2):279-89.
doi: 10.1006/abio.2001.5030.

High-performance liquid chromatography-based determination of total isothiocyanate levels in human plasma: application to studies with 2-phenethyl isothiocyanate

Affiliations

High-performance liquid chromatography-based determination of total isothiocyanate levels in human plasma: application to studies with 2-phenethyl isothiocyanate

L Liebes et al. Anal Biochem. .

Abstract

Dietary and pharmacologic isothiocyanates (ITCs) may play a role in reducing the risk of certain cancers. The quantification of ITCs in humans is important both for epidemiological and pharmacokinetic studies. We describe a modification of an HPLC-based assay of urinary ITCs for use with human plasma. The assay utilizes the cyclocondensation reaction of 1,2-benzenedithiol with ITCs present in human plasma, followed by a two-step hexane extraction and analysis by HPLC using UV detection at 365 nm. The method shows linearity and reproducibility with human plasma over a range of 49-3003 nM phenethyl isothiocyanate (PEITC) (r(2) = 0.996 +/- 0.003). A similar degree of linearity was seen with two other biologically occurring conjugates of PEITC: PEITC--N-acetylcysteine (PEITC--NAC) and PEITC--glutathione (PEITC--GSH). The recovery of PEITC assessed on multiple days was 96.6 +/- 1.5% and was 100% for PEITC--GSH and PEITC--NAC. The reproducibility of the assay on multiday samplings showed a mean %CV of 6.5 +/- 0.3% for PEITC, 6.4 +/- 4.3 for PEITC--NAC and 12.3 +/- 3.9 for PEITC--GSH. In clinical studies, mean plasma ITC level of 413 +/- 193 nM PEITC equivalents was determined for a non-dietary-controlled group of 23 subjects. Multiday analysis data from pharmacokinetic plasma sets of 3 subjects taking a single dose of PEITC at 40 mg showed a good CV (range: 16-21%). The applicability of the methodology to pharmacokinetic studies of PEITC in humans is demonstrated.

PubMed Disclaimer

Publication types

LinkOut - more resources