Stability of visual field enlargements following computer-based restitution training -- results of a follow-up
- PMID: 11404808
- DOI: 10.1076/jcen.23.3.297.1180
Stability of visual field enlargements following computer-based restitution training -- results of a follow-up
Abstract
In a previous randomized placebo-controlled clinical trial, we observed significant visual field enlargements induced by computer-based restitution training in patients with cerebral lesions (Kasten et al., Nature med., 4, 1998, 1083-87). Now we asked the question whether this effect is stable after training was discontinued? Here we report data of a follow-up study after a training-free interval (mean 23.5 +/- 2.3 months after end of therapy). 16 patients of the original restitution group and 6 patients of the placebo group were re-examined. On average, in high resolution computer campimetry (stimulus detection: PeriMa, form recognition: PeriForm, color perception: PeriColor) as well as in conventional automatic perimetry (TAP-2000) both groups showed no significant decline in the number of correctly detected stimuli after training was discontinued. However, cluster analysis revealed three different types of patients, who showed either increase (Type-I), decrease (Type-II) or stability (Type-III) in performance. We propose that many patients learn to use the regained visual capacities not only in the setting of a computer training but also in every day life, while other patients do not use the areas of restored vision and show a decrease of visual functions after the end of training. The Type-I group does not need continuous training, while the Type-II group may benefit from phases of refreshment exercises.
Similar articles
-
Computer-based training of stimulus detection improves color and simple pattern recognition in the defective field of hemianopic subjects.J Cogn Neurosci. 2000 Nov;12(6):1001-12. doi: 10.1162/08989290051137530. J Cogn Neurosci. 2000. PMID: 11177420 Clinical Trial.
-
Vision restoration training for glaucoma: a randomized clinical trial.JAMA Ophthalmol. 2014 Apr 1;132(4):381-9. doi: 10.1001/jamaophthalmol.2013.7963. JAMA Ophthalmol. 2014. PMID: 24504128 Clinical Trial.
-
Long-term learning of visual functions in patients after brain damage.Behav Brain Res. 2008 Aug 5;191(1):32-42. doi: 10.1016/j.bbr.2008.03.005. Epub 2008 Mar 14. Behav Brain Res. 2008. PMID: 18436312 Clinical Trial.
-
Approaches to rehabilitation for visual field defects following brain lesions.Expert Rev Med Devices. 2009 May;6(3):291-305. doi: 10.1586/erd.09.8. Expert Rev Med Devices. 2009. PMID: 19419286 Review.
-
Stroke and visual rehabilitation.Top Stroke Rehabil. 2008 Jan-Feb;15(1):27-36. doi: 10.1310/tsr1501-27. Top Stroke Rehabil. 2008. PMID: 18250071 Review.
Cited by
-
Visual rehabilitation: visual scanning, multisensory stimulation and vision restoration trainings.Front Behav Neurosci. 2015 Jul 27;9:192. doi: 10.3389/fnbeh.2015.00192. eCollection 2015. Front Behav Neurosci. 2015. PMID: 26283935 Free PMC article. Review.
-
The effect of visual training for patients with visual field defects due to brain damage: a systematic review.J Neurol Neurosurg Psychiatry. 2007 Jun;78(6):555-64. doi: 10.1136/jnnp.2006.103853. Epub 2006 Nov 29. J Neurol Neurosurg Psychiatry. 2007. PMID: 17135455 Free PMC article.
-
Community-based trial of a peripheral prism visual field expansion device for hemianopia.Arch Ophthalmol. 2008 May;126(5):657-64. doi: 10.1001/archopht.126.5.657. Arch Ophthalmol. 2008. PMID: 18474776 Free PMC article. Clinical Trial.
-
Clinical treatment options for patients with homonymous visual field defects.Clin Ophthalmol. 2008 Mar;2(1):93-102. doi: 10.2147/opth.s2371. Clin Ophthalmol. 2008. PMID: 19668392 Free PMC article.
-
Telerehabilitation for people with low vision.Cochrane Database Syst Rev. 2020 Feb 27;2(2):CD011019. doi: 10.1002/14651858.CD011019.pub3. Cochrane Database Syst Rev. 2020. Update in: Cochrane Database Syst Rev. 2023 Jan 13;1:CD011019. doi: 10.1002/14651858.CD011019.pub4. PMID: 32102114 Free PMC article. Updated.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous