Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2001 Jul;42(8):1841-6.

Reliable measurement of mouse intraocular pressure by a servo-null micropipette system

Affiliations
  • PMID: 11431452

Reliable measurement of mouse intraocular pressure by a servo-null micropipette system

M Y Avila et al. Invest Ophthalmol Vis Sci. 2001 Jul.

Abstract

Purpose: To develop a reliable technique for measuring intraocular pressure (IOP) in the mouse.

Methods: An electrophysiologic approach-the servo-null micropipette system (SNMS)-for measuring hydrostatic pressure was adapted for the mouse eye. Fine-tipped (5 microm in diameter) micropipettes were advanced across the cornea with a piezoelectric micromanipulator, and the IOP was continuously monitored for up to 46 minutes.

Results: The micropipette tip was visualized in the anterior chamber. With the SNMS, the IOP of black Swiss outbred mice under ketamine anesthesia was 17.8 +/- 0.4 mm Hg, higher than values previously estimated in inbred mouse strains by a larger bore microneedle manometric technique. After withdrawal of the micropipette, a second penetration led to a similar level of IOP. Hypotonic solutions increased and hypertonic solutions decreased IOP. Drugs that decrease inflow (acetazolamide, timolol) or increase outflow facility (pilocarpine, latanoprost) in primates and humans lowered steady state IOP in the mouse. The transient initial increase in IOP produced by pilocarpine reported in other animals was also observed in the mouse. Xylazine-ketamine anesthesia lowered IOP substantially in comparison with systemic anesthesia with either ketamine or tribromoethanol alone.

Conclusions: The SNMS is the first reliable, reproducible method for measuring mouse IOP. The mouse IOP is sensitive not only to drugs known to reduce aqueous humor inflow but also to drugs that increase aqueous humor outflow facility in the eyes of primates and humans. The development of the SNMS is an enabling step in the use of the mouse for glaucoma research, including molecular genetics, molecular pharmacology, and the search for novel antiglaucoma drugs.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources