Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2001 Jun;13(3):199-210.
doi: 10.1046/j.1365-2982.2001.00259.x.

Oesophageal pressure-cross-sectional area distributions and secondary peristalsis in relation to subclassification of systemic sclerosis

Affiliations

Oesophageal pressure-cross-sectional area distributions and secondary peristalsis in relation to subclassification of systemic sclerosis

G E Villadsen et al. Neurogastroenterol Motil. 2001 Jun.

Abstract

The aim of the present study was to correlate the severity of oesophageal motor dysfunction with the severity of cutaneous disease in systemic sclerosis (SS). Patients were divided into three groups based on the degree of skin involvement: type I, acrosclerosis distal to the wrist; type II, scleroderma extending above the wrist in proximal direction; type III, diffuse cutaneous systemic sclerosis. Impedance planimetry employing distensions with pressures up to 5 kPa with the concomitant measurement of oesophageal cross-sectional area (CSA) was used in combination with standard oesophageal manometry. Measurements were made at 7 and 15 cm above the lower oesophageal sphincter (LOS). Thirty patients (16 type I, six type II and eight type III patients) and 23 normal controls were included. LOS pressure was lower in SS patients than in normal patients, with the lowest values in type III. The CSAs were higher in SS patients than in controls at both sites (P < 0.001). The CSAs at the distal site were highest in type III, as compared to type I and II (P < 0.03). The CSA at the highest induced pressure (5.0 kPa) was 613 +/- 45, 719 +/- 79, and 808 +/- 115 mm2 in types I, II and III, respectively. No differences in CSA were found at the proximal site between the three types of SS. The distensibility did not differ between SS and normal patients at the distal site. The distensibility was lowest in SS patients (P < 0.001) at the proximal distension site. The distensibility did not vary with the type of SS at either site. Significant differences in contraction frequency of the secondary peristalsis as function of wall tension were demonstrated between the SS patients and controls at the distal site (P < 0.05). No differences were found at the proximal site. The contraction frequency and amplitude at the distal and proximal sites did not differ among the three types. In conclusion for most parameters studied, SS patients differed from normal patients. Among SS types, the most pronounced changes were found in type III.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources