7T vs. 4T: RF power, homogeneity, and signal-to-noise comparison in head images
- PMID: 11443707
- DOI: 10.1002/mrm.1156
7T vs. 4T: RF power, homogeneity, and signal-to-noise comparison in head images
Abstract
Signal-to-noise ratio (SNR), RF field (B(1)), and RF power requirement for human head imaging were examined at 7T and 4T magnetic field strengths. The variation in B(1) magnitude was nearly twofold higher at 7T than at 4T ( approximately 42% compared to approximately 23%). The power required for a 90 degrees pulse in the center of the head at 7T was approximately twice that at 4T. The SNR averaged over the brain was at least 1.6 times higher at 7T compared to 4T. These experimental results were consistent with calculations performed using a human head model and Maxwell's equations. Magn Reson Med 46:24-30, 2001.
Copyright 2001 Wiley-Liss, Inc.
Similar articles
-
Image-guided radio-frequency gain calibration for high-field MRI.NMR Biomed. 2010 May;23(4):368-74. doi: 10.1002/nbm.1471. Epub 2009 Dec 15. NMR Biomed. 2010. PMID: 20014333 Free PMC article.
-
Design of universal parallel-transmit refocusing kT -point pulses and application to 3D T2 -weighted imaging at 7T.Magn Reson Med. 2018 Jul;80(1):53-65. doi: 10.1002/mrm.27001. Epub 2017 Nov 29. Magn Reson Med. 2018. PMID: 29193250
-
Signal-to-noise ratio and MR tissue parameters in human brain imaging at 3, 7, and 9.4 tesla using current receive coil arrays.Magn Reson Med. 2016 Feb;75(2):801-9. doi: 10.1002/mrm.25677. Epub 2015 Mar 29. Magn Reson Med. 2016. PMID: 25820458
-
Low-field MRI: An MR physics perspective.J Magn Reson Imaging. 2019 Jun;49(6):1528-1542. doi: 10.1002/jmri.26637. Epub 2019 Jan 13. J Magn Reson Imaging. 2019. PMID: 30637943 Free PMC article. Review.
-
Evolution of UHF Body Imaging in the Human Torso at 7T: Technology, Applications, and Future Directions.Top Magn Reson Imaging. 2019 Jun;28(3):101-124. doi: 10.1097/RMR.0000000000000202. Top Magn Reson Imaging. 2019. PMID: 31188271 Free PMC article. Review.
Cited by
-
[Problems and chances of high field magnetic resonance imaging].Radiologe. 2013 May;53(5):401-10. doi: 10.1007/s00117-012-2344-x. Radiologe. 2013. PMID: 23592011 German.
-
In vivo irreversible and reversible transverse relaxation rates in human cerebral cortex via line scans at 7 T with 250 micron resolution perpendicular to the cortical surface.Magn Reson Imaging. 2022 Jul;90:44-52. doi: 10.1016/j.mri.2022.04.001. Epub 2022 Apr 6. Magn Reson Imaging. 2022. PMID: 35398027 Free PMC article.
-
CONtrast Conformed Electrical Properties Tomography (CONCEPT) Based on Multi- Channel Transmission and Alternating Direction Method of Multipliers.IEEE Trans Med Imaging. 2019 Feb;38(2):349-359. doi: 10.1109/TMI.2018.2865121. Epub 2018 Aug 13. IEEE Trans Med Imaging. 2019. PMID: 30106715 Free PMC article.
-
Visualization of microvascularity in glioblastoma multiforme with 8-T high-spatial-resolution MR imaging.AJNR Am J Neuroradiol. 2002 Oct;23(9):1553-6. AJNR Am J Neuroradiol. 2002. PMID: 12372746 Free PMC article.
-
In-vivo and numerical analysis of the eigenmodes produced by a multi-level Tic-Tac-Toe head transmit array for 7 Tesla MRI.PLoS One. 2018 Nov 27;13(11):e0206127. doi: 10.1371/journal.pone.0206127. eCollection 2018. PLoS One. 2018. PMID: 30481187 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical