Possibilities and limitations of automated platelet counting procedures in the thrombocytopenic range
- PMID: 11446656
- DOI: 10.1055/s-2001-15252
Possibilities and limitations of automated platelet counting procedures in the thrombocytopenic range
Abstract
The clinical decision to proceed with prophylactic platelet transfusions is widely based on trigger points for platelet counts being equal to 20, 10, or even 5 x 10(9)/L. But an increasing number of publications show evidence that the conventional automated platelet counting methods are unable to provide consistently accurate results in this lower thrombocytopenic range. These measurement errors are mainly associated with the most commonly used impedance principle; optical methods seem to be more precise. The problems of counting imprecision in the low thrombocytopenic range can be avoided with direct or indirect immunological counting methods using monoclonal antibodies or by time-consuming manual procedures. But how should new counting procedures be evaluated? Which method should be used as the "gold standard" for platelet counting? A way out of this apparent dilemma is the application of a statistical procedure as proposed by Gautschi et al. This mathematical model allows a reference method independent evaluation of new methods by calculation of the limits of detection (LD) and limits of quantification (LQ) based on the imprecision profile of the investigated method. Using this evaluation procedure, it can be shown that immunological automated counting methods can provide reliable, sufficient, and prompt platelet counts, especially in the thrombocytopenic range.
Similar articles
-
Problems with platelet counting in thrombocytopenia. A rapid manual method to measure low platelet counts.Semin Thromb Hemost. 2001 Jun;27(3):237-43. doi: 10.1055/s-2001-15253. Semin Thromb Hemost. 2001. PMID: 11446657
-
Continuing developments with the automated platelet count.Int J Lab Hematol. 2007 Apr;29(2):77-91. doi: 10.1111/j.1751-553X.2007.00909.x. Int J Lab Hematol. 2007. PMID: 17474881 Review.
-
Accuracy of platelet counting haematology analysers in severe thrombocytopenia and potential impact on platelet transfusion.Br J Haematol. 2005 Feb;128(4):520-5. doi: 10.1111/j.1365-2141.2004.05352.x. Br J Haematol. 2005. PMID: 15686462
-
Enumeration of platelets by multiparameter flow cytometry using platelet-specific antibodies and fluorescent reference particles.Clin Lab Haematol. 1995 Jun;17(2):163-72. Clin Lab Haematol. 1995. PMID: 8536420
-
Methods for counting platelets in severe thrombocytopenia.Curr Hematol Rep. 2006 Mar;5(1):70-5. Curr Hematol Rep. 2006. PMID: 16537049 Review.
Cited by
-
Estimation of Total Platelet Count From Peripheral Blood Smear Needs a Correction Factor.Cureus. 2022 Aug 23;14(8):e28327. doi: 10.7759/cureus.28327. eCollection 2022 Aug. Cureus. 2022. PMID: 36168371 Free PMC article.
-
Effectiveness of two methods for preparation of autologous platelet-rich plasma: an experimental study in rabbits.Eur J Dent. 2010 Oct;4(4):395-402. Eur J Dent. 2010. PMID: 20922159 Free PMC article.
-
Comparative (Quantitative and Qualitative) Analysis of Three Different Reagents for Preparation of Platelet-Rich Plasma for Hair Rejuvenation.J Cutan Aesthet Surg. 2018 Jul-Sep;11(3):127-131. doi: 10.4103/JCAS.JCAS_108_18. J Cutan Aesthet Surg. 2018. PMID: 30533986 Free PMC article.
-
Evaluation on clinical performance of the new low-value platelet measurement mode (PLT-8X) of BC-6800Plus.Ann Transl Med. 2022 Jun;10(12):692. doi: 10.21037/atm-22-1501. Ann Transl Med. 2022. PMID: 35845540 Free PMC article.
-
Human erythrocyte fragmentation during ex-vivo pig organ perfusion.Xenotransplantation. 2022 Mar;29(2):e12729. doi: 10.1111/xen.12729. Epub 2022 Feb 2. Xenotransplantation. 2022. PMID: 35112383 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Research Materials