Effect of altering conditions of the sequence method on baroreflex sensitivity
- PMID: 11446718
- DOI: 10.1097/00004872-200107000-00013
Effect of altering conditions of the sequence method on baroreflex sensitivity
Abstract
Background: The sequence method is widely used as a simple, non-invasive measure of baroreflex sensitivity (BRS). This technique, originally described in anaesthetized cats, has been transferred virtually unchanged to humans, without evidence that the optimal values in cats are the same as those in patients with cardiovascular disease.
Objective: To study the effect of altering the components of the sequence method on the measured BRS in patients with chronic heart failure (CHF) and in normal individuals.
Methods: Eighty patients with CHF [aged 62 +/- 12 years (mean +/- SD)] and 40 normal control individuals [aged 38 +/- 15 years (mean +/- SD)] underwent measurement of heart rate and non-invasive blood pressure. Altering only the shift between blood pressure and R-R interval and the required correlation coefficient of the regression line had no effect on the value of BRS, but had a significant effect on the number of valid sequences. Alteration of the blood pressure or R-R interval thresholds, however, affected not only the number of valid sequences, but also the value of BRS in both groups. In normal controls, agreement with the bolus phenylephrine method was improved by increasing the blood pressure threshold, although this led to a reduction in the number of valid sequences. In patients with CHF, agreement was optimized by decreasing both the blood pressure and R-R interval thresholds. This also had the effect of increasing the number of valid sequences.
Conclusion: Changes should be made to this technique, to optimize its validity in conscious humans, particularly when applied to patients with attenuated BRS.
Similar articles
-
Arterial baroreflex modulation of heart rate in chronic heart failure: clinical and hemodynamic correlates and prognostic implications.Circulation. 1997 Nov 18;96(10):3450-8. doi: 10.1161/01.cir.96.10.3450. Circulation. 1997. PMID: 9396441
-
A noninvasive measure of baroreflex sensitivity without blood pressure measurement.Am Heart J. 2002 Mar;143(3):441-7. doi: 10.1067/mhj.2002.121263. Am Heart J. 2002. PMID: 11868049
-
Development of a new method for assessing the cardiac baroreflex: response to downward tilting in patients with diabetes mellitus.Heart. 2001 Dec;86(6):643-8. doi: 10.1136/heart.86.6.643. Heart. 2001. PMID: 11711458 Free PMC article.
-
Assessment of baroreflex sensitivity from spontaneous oscillations of blood pressure and heart rate: proven clinical value?Physiol Meas. 2015 Apr;36(4):741-53. doi: 10.1088/0967-3334/36/4/741. Epub 2015 Mar 23. Physiol Meas. 2015. PMID: 25798657 Review.
-
[Baroreflex sensitivity: diagnostic importance, methods of determination and a model of baroreflex blood-pressure regulation].Cesk Fysiol. 2013;62(1):10-8. Cesk Fysiol. 2013. PMID: 23821958 Review. Czech.
Cited by
-
Baroreflex sensitivity estimation by the sequence method with delayed signals.Clin Auton Res. 2012 Dec;22(6):289-97. doi: 10.1007/s10286-012-0173-7. Epub 2012 Aug 9. Clin Auton Res. 2012. PMID: 22875549
-
Age-related reflex responses from peripheral and central chemoreceptors in healthy men.Clin Auton Res. 2014 Dec;24(6):285-96. doi: 10.1007/s10286-014-0263-9. Epub 2014 Nov 25. Clin Auton Res. 2014. PMID: 25421997 Free PMC article.
-
Low ventilatory responsiveness to transient hypoxia or breath-holding predicts fast marathon performance in healthy middle-aged and older men.Sci Rep. 2021 May 13;11(1):10255. doi: 10.1038/s41598-021-89766-4. Sci Rep. 2021. PMID: 33986451 Free PMC article.
-
Changes in autonomic balance in patients with decompensated chronic heart failure.Clin Auton Res. 2011 Feb;21(1):47-54. doi: 10.1007/s10286-010-0089-z. Epub 2010 Nov 16. Clin Auton Res. 2011. PMID: 21080025
-
Contribution of Baroreceptor Function to Pain Perception and Perioperative Outcomes.Anesthesiology. 2019 Apr;130(4):634-650. doi: 10.1097/ALN.0000000000002510. Anesthesiology. 2019. PMID: 30418212 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous