Self-monitoring of blood glucose levels and glycemic control: the Northern California Kaiser Permanente Diabetes registry
- PMID: 11448654
- DOI: 10.1016/s0002-9343(01)00742-2
Self-monitoring of blood glucose levels and glycemic control: the Northern California Kaiser Permanente Diabetes registry
Abstract
Purpose: We sought to evaluate the effectiveness of self-monitoring blood glucose levels to improve glycemic control.
Subjects and methods: A cohort design was used to assess the relation between self-monitoring frequency (1996 average daily glucometer strip utilization) and the first glycosylated hemoglobin (HbA1c) level measured in 1997. The study sample included 24,312 adult patients with diabetes who were members of a large, group model, managed care organization. We estimated the difference between HbA1c levels in patients who self-monitored at frequencies recommended by the American Diabetes Association compared with those who monitored less frequently or not at all. Models were adjusted for age, sex, race, education, occupation, income, duration of diabetes, medication refill adherence, clinic appointment "no show" rate, annual eye exam attendance, use of nonpharmacological (diet and exercise) diabetes therapy, smoking, alcohol consumption, hospitalization and emergency room visits, and the number of daily insulin injections.
Results: Self-monitoring among patients with type 1 diabetes (> or = 3 times daily) and pharmacologically treated type 2 diabetes (at least daily) was associated with lower HbA1c levels (1.0 percentage points lower in type 1 diabetes and 0.6 points lower in type 2 diabetes) than was less frequent monitoring (P < 0.0001). Although there are no specific recommendations for patients with nonpharmacologically treated type 2 diabetes, those who practiced self-monitoring (at any frequency) had a 0.4 point lower HbA1c level than those not practicing at all (P < 0.0001).
Conclusion: More frequent self-monitoring of blood glucose levels was associated with clinically and statistically better glycemic control regardless of diabetes type or therapy. These findings support the clinical recommendations suggested by the American Diabetes Association.
Similar articles
-
Association of Real-time Continuous Glucose Monitoring With Glycemic Control and Acute Metabolic Events Among Patients With Insulin-Treated Diabetes.JAMA. 2021 Jun 8;325(22):2273-2284. doi: 10.1001/jama.2021.6530. JAMA. 2021. PMID: 34077502 Free PMC article.
-
Self-monitoring of blood glucose: language and financial barriers in a managed care population with diabetes.Diabetes Care. 2000 Apr;23(4):477-83. doi: 10.2337/diacare.23.4.477. Diabetes Care. 2000. PMID: 10857938
-
Color record in self-monitoring of blood glucose improves glycemic control by better self-management.Diabetes Technol Ther. 2014 Jul;16(7):447-53. doi: 10.1089/dia.2013.0301. Epub 2014 Feb 7. Diabetes Technol Ther. 2014. PMID: 24506479 Clinical Trial.
-
Monitoring glycemic control: the importance of self-monitoring of blood glucose.Am J Med. 2005 Sep;118(Suppl 9A):12S-19S. doi: 10.1016/j.amjmed.2005.07.052. Am J Med. 2005. PMID: 16224938 Review.
-
Capillary blood glucose monitoring.Nurs Stand. 2007 May 30-Jun 5;21(38):35-8. doi: 10.7748/ns2007.05.21.38.35.c4561. Nurs Stand. 2007. PMID: 17569467 Review.
Cited by
-
RSSDI-ESI Clinical Practice Recommendations for the Management of Type 2 Diabetes Mellitus 2020.Indian J Endocrinol Metab. 2020 Jan-Feb;24(1):1-122. doi: 10.4103/ijem.IJEM_225_20. Indian J Endocrinol Metab. 2020. PMID: 32699774 Free PMC article. No abstract available.
-
An algorithm to identify medication nonpersistence using electronic pharmacy databases.J Am Med Inform Assoc. 2015 Sep;22(5):957-61. doi: 10.1093/jamia/ocv054. Epub 2015 Jun 15. J Am Med Inform Assoc. 2015. PMID: 26078413 Free PMC article.
-
Telemedical artificial pancreas: PARIS (Pancreas Artificial Telemedico Inteligente) research project.Diabetes Care. 2009 Nov;32 Suppl 2(Suppl 2):S211-6. doi: 10.2337/dc09-S313. Diabetes Care. 2009. PMID: 19875554 Free PMC article. No abstract available.
-
Performance evaluation and labeling comprehension of a new blood glucose monitoring system with integrated information management.J Diabetes Sci Technol. 2011 Sep 1;5(5):1144-53. doi: 10.1177/193229681100500516. J Diabetes Sci Technol. 2011. PMID: 22027308 Free PMC article.
-
Evaluation of a New Noninvasive Glucose Monitoring Device by Means of Standardized Meal Experiments.J Diabetes Sci Technol. 2018 Nov;12(6):1178-1183. doi: 10.1177/1932296818758769. Epub 2018 Feb 16. J Diabetes Sci Technol. 2018. PMID: 29451016 Free PMC article. Clinical Trial.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Medical