Effects of the glenoid labrum and glenohumeral abduction on stability of the shoulder joint through concavity-compression : an in vitro study
- PMID: 11451977
- DOI: 10.2106/00004623-200107000-00013
Effects of the glenoid labrum and glenohumeral abduction on stability of the shoulder joint through concavity-compression : an in vitro study
Abstract
Background: Although the glenohumeral joint is the most mobile articulation of the human body, it is known to exhibit ball-and-socket kinematics. Compression into the glenoid labral concavity keeps the humeral head centered. The purpose of the present study was to determine the effects of joint position on glenohumeral stability through concavity-compression.
Methods: Ten cadaveric shoulders were tested. The glenoid was mounted horizontally onto a six-component load-cell while the humerus was clamped to a vertically unconstrained slide. An x-y stage translated the load-cell with the glenoid underneath the humeral head in eight different directions. Compressive loads of 20, 40, and 60 N were applied. The tests were repeated in 0 degrees, 30 degrees, 60 degrees, and 90 degrees of glenohumeral abduction with and without the labrum. Relative translations between the glenoid and the humeral head and the forces resisting translation were recorded. Then the stability ratio, defined as the peak translational force divided by the applied compressive force, was calculated.
Results: The average stability ratio was higher in the hanging-arm position than it was in glenohumeral abduction. The highest stability ratio was detected in the inferior direction (59.8% 7.7%) when the labrum was intact and in the superior direction (53.3% 7.9%) when the labrum had been resected. Under both conditions, the anterior direction was associated with the lowest stability ratio (32.0% 4.4% with the labrum and 30.4% 4.1% without the labrum). Resection of the glenoid labrum resulted in an average decrease in the stability ratio of 9.6% 1.7%. With increasing compressive load, the average stability ratio slightly decreased.
Conclusions: Glenohumeral stability through concavity-compression was greater in the hanging-arm position than it was in glenohumeral abduction. The average contribution of the labrum to glenohumeral stability through concavity-compression was approximately 10%, about one-half of the value previously reported. With the labrum intact, the glenohumeral joint was most stable in the inferior direction. Without the labrum, it was most stable in the superior direction. Under both conditions, it was least stable in the anterior direction. Glenohumeral joint stability through concavity-compression decreases with higher compressive loads.
Comment in
-
The biomechanics of glenohumeral stability.J Bone Joint Surg Am. 2002 Mar;84(3):495-6. doi: 10.2106/00004623-200203000-00033. J Bone Joint Surg Am. 2002. PMID: 11886928 No abstract available.
Similar articles
-
Effects of varying locations for biceps tendon tenotomy and superior labral integrity on shoulder stability in a cadaveric concavity-compression model.Arthroscopy. 2014 Dec;30(12):1557-61. doi: 10.1016/j.arthro.2014.06.012. Epub 2014 Aug 14. Arthroscopy. 2014. PMID: 25129863
-
Effect of joint compression on inferior stability of the glenohumeral joint.J Shoulder Elbow Surg. 1999 Jan-Feb;8(1):31-6. doi: 10.1016/s1058-2746(99)90051-4. J Shoulder Elbow Surg. 1999. PMID: 10077793
-
Glenohumeral stability from concavity-compression: A quantitative analysis.J Shoulder Elbow Surg. 1993 Jan;2(1):27-35. doi: 10.1016/S1058-2746(09)80134-1. Epub 2009 Feb 19. J Shoulder Elbow Surg. 1993. PMID: 22959294
-
Anatomical, functional and biomechanical review of the glenoid labrum.J Anat. 2022 Apr;240(4):761-771. doi: 10.1111/joa.13582. Epub 2021 Nov 1. J Anat. 2022. PMID: 34725812 Free PMC article. Review.
-
The shoulder joint complex in the throwing motion.J Shoulder Elbow Surg. 2024 Feb;33(2):443-449. doi: 10.1016/j.jse.2023.06.031. Epub 2023 Jul 26. J Shoulder Elbow Surg. 2024. PMID: 37499784 Review.
Cited by
-
Case Report: A complex congenital bilateral multidirectional glenohumeral hyperlaxity with instability: surgical, anatomical, and forensic insights.Front Surg. 2025 Jun 2;12:1578404. doi: 10.3389/fsurg.2025.1578404. eCollection 2025. Front Surg. 2025. PMID: 40529889 Free PMC article.
-
Multidirectional Shoulder Instability: Arthroscopic Labral Augmentation.Arthrosc Tech. 2017 Feb 20;6(1):e219-e225. doi: 10.1016/j.eats.2016.09.025. eCollection 2017 Feb. Arthrosc Tech. 2017. PMID: 28409104 Free PMC article.
-
The Biomechanical Importance of Bone Block Positioning in Glenoid Augmentation: Every Millimeter Matters.Am J Sports Med. 2025 Apr;53(5):1164-1170. doi: 10.1177/03635465251322796. Epub 2025 Mar 2. Am J Sports Med. 2025. PMID: 40025625 Free PMC article.
-
Multidirectional instability of the shoulder: biomechanics, clinical presentation, and treatment strategies.Eur J Orthop Surg Traumatol. 2015 Aug;25(6):975-85. doi: 10.1007/s00590-015-1606-5. Epub 2015 Feb 1. Eur J Orthop Surg Traumatol. 2015. PMID: 25638224 Review.
-
Effect of Anterior Glenoid Chondrolabral Defects on Anterior Glenohumeral Stability: A Biomechanical Study.Orthop J Sports Med. 2022 Oct 31;10(10):23259671221130700. doi: 10.1177/23259671221130700. eCollection 2022 Oct. Orthop J Sports Med. 2022. PMID: 36338354 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources