Advanced cardiac MR imaging of ischemic heart disease
- PMID: 11452080
- DOI: 10.1148/radiographics.21.4.g01jl281047
Advanced cardiac MR imaging of ischemic heart disease
Abstract
Important advances in rapid magnetic resonance (MR) imaging technology and its application to cardiovascular imaging have been made during the past decade. High-field-strength clinical magnets, high-performance gradient hardware, and ultrafast pulse sequence technology are rapidly making the vision of a comprehensive "one-stop shop" cardiac MR imaging examination a reality. This examination is poised to have a significant effect on the management of coronary artery disease by means of assessment of wall motion with tagging and pharmacologic stress testing, evaluation of the coronary microvasculature with perfusion imaging, and direct visualization of the coronary arteries with MR coronary angiography. This article reviews current state-of-the-art pulse sequence technology and its application to the evaluation of ischemic heart disease by means of MR tagging with dobutamine stress testing, MR perfusion imaging, and MR coronary angiography. Cutting edge areas of research in coil design and exciting new areas of metabolic and oxygen level-dependent imaging are also explored.
Similar articles
-
Prognostic value of cardiac magnetic resonance stress tests: adenosine stress perfusion and dobutamine stress wall motion imaging.Circulation. 2007 Apr 3;115(13):1769-76. doi: 10.1161/CIRCULATIONAHA.106.652016. Epub 2007 Mar 12. Circulation. 2007. PMID: 17353441 Clinical Trial.
-
[Dobutamine stress magnetic resonance imaging (DS-MRI), a valuable tool for the diagnosis of ischemic heart disease].Ned Tijdschr Geneeskd. 2002 Jul 13;146(28):1327-32. Ned Tijdschr Geneeskd. 2002. PMID: 12148221 Dutch.
-
Dobutamine stress cardiovascular magnetic resonance imaging in patients after invasive coronary revascularization with stent placement.Acta Radiol. 2009 Dec;50(10):1134-41. doi: 10.3109/02841850903216692. Acta Radiol. 2009. PMID: 19922310
-
Magnetic resonance imaging for ischemic heart disease.J Magn Reson Imaging. 2007 Jul;26(1):3-13. doi: 10.1002/jmri.20976. J Magn Reson Imaging. 2007. PMID: 17659549 Review.
-
MR evaluation of myocardial ischemia and infarction.Top Magn Reson Imaging. 1995 Fall;7(4):218-31. Top Magn Reson Imaging. 1995. PMID: 8534493 Review.
Cited by
-
Diagnostic value of contrast-enhanced cardiac magnetic resonance in patients with acute coronary syndrome with normal coronary arteries.Jpn J Radiol. 2015 Jul;33(7):410-7. doi: 10.1007/s11604-015-0440-3. Epub 2015 May 29. Jpn J Radiol. 2015. PMID: 26018966
-
Influence of high magnetic field strengths and parallel acquisition strategies on image quality in cardiac 2D CINE magnetic resonance imaging: comparison of 1.5 T vs. 3.0 T.Eur Radiol. 2005 Aug;15(8):1586-97. doi: 10.1007/s00330-005-2768-z. Epub 2005 May 5. Eur Radiol. 2005. PMID: 15875193
-
MRI for the diagnosis of left ventricular apical ballooning syndrome (LVABS).Eur Radiol. 2008 May;18(5):947-54. doi: 10.1007/s00330-008-0853-9. Epub 2008 Jan 31. Eur Radiol. 2008. PMID: 18236045
-
Contrast-enhanced cardiac MR imaging.Eur Radiol. 2003 Nov;13 Suppl 3:N11-8. doi: 10.1007/s00330-003-0002-4. Eur Radiol. 2003. PMID: 15015876 Review. No abstract available.
-
The 20 year evolution of dobutamine stress cardiovascular magnetic resonance.J Cardiovasc Magn Reson. 2010 Oct 26;12(1):59. doi: 10.1186/1532-429X-12-59. J Cardiovasc Magn Reson. 2010. PMID: 20977757 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous