New trends in the application of electron ionization to liquid chromatography-mass spectrometry interfacing
- PMID: 11455563
- DOI: 10.1002/mas.1004
New trends in the application of electron ionization to liquid chromatography-mass spectrometry interfacing
Abstract
I. Introduction 88 II. Cap-EI Interface 90 A. Interface Performance 92 III. Direct-EI Interface 93 A. Interface Performance 97 IV. Conclusions 103 Acknowledgments 103 References 103 --Two recent approaches for coupling capillary scale liquid chromatography and electron ionization mass spectrometry are reviewed and discussed. The first one, Cap-EI, is the latest evolution of the micro-scale particle beam interface, in which the nebulizer has been optimized to overcome the limitations of the former approach, in terms of sensitivity and linearity. It can be easily hosted in pre-existing instruments without major modifications and can use helium and the less-expensive nitrogen to generate library-matchable electron ionization spectra. The second one is a miniaturized interface for nano- and micro-HPLC, in which the interfacing process takes place into a suitably modified ion source. Because the eluate from the column is completely transferred into the ion source for ionization, superior sensitivity, linearity, and reproducibility are obtained. No signs of chemical ionization are observed at flow rates up to 1.5 microL/min. These two interfaces demonstrate that electron ionization can be successfully used for the analysis of small-medium molecules of various polarities, and also at the trace level. The possibility to record library-matchable electron ionization spectra offers the analyst a powerful tool that can be particularly useful in real-world applications.
Copyright 2001 John Wiley & Sons, Inc.
Similar articles
-
Liquid chromatography-electron ionization mass spectrometry: fields of application and evaluation of the performance of a Direct-EI interface.Mass Spectrom Rev. 2005 Nov-Dec;24(6):978-89. doi: 10.1002/mas.20054. Mass Spectrom Rev. 2005. PMID: 15900616 Review.
-
Advanced liquid chromatography-mass spectrometry interface based on electron ionization.Anal Chem. 2007 Jul 15;79(14):5364-72. doi: 10.1021/ac070468l. Epub 2007 Jun 15. Anal Chem. 2007. PMID: 17569502
-
New liquid chromatography/electron ionization mass spectrometry methods in water analysis.Ann Chim. 2002 Jul-Aug;92(7-8):623-36. Ann Chim. 2002. PMID: 12185745
-
Analysis of boronic acids by nano liquid chromatography-direct electron ionization mass spectrometry.Anal Chem. 2010 May 15;82(10):4194-200. doi: 10.1021/ac1004585. Anal Chem. 2010. PMID: 20411924
-
Sensitivity enhancement in liquid chromatography/atmospheric pressure ionization mass spectrometry using derivatization and mobile phase additives.J Chromatogr B Analyt Technol Biomed Life Sci. 2005 Oct 25;825(2):98-110. doi: 10.1016/j.jchromb.2005.04.021. J Chromatogr B Analyt Technol Biomed Life Sci. 2005. PMID: 15897015 Review.
Cited by
-
NanoLC-EI-MS: Perspectives in Biochemical Analysis.Int J Mol Sci. 2023 Jul 21;24(14):11746. doi: 10.3390/ijms241411746. Int J Mol Sci. 2023. PMID: 37511506 Free PMC article. Review.
-
Quantitation of DNA adducts by stable isotope dilution mass spectrometry.Chem Res Toxicol. 2012 Oct 15;25(10):2007-35. doi: 10.1021/tx3002548. Epub 2012 Aug 28. Chem Res Toxicol. 2012. PMID: 22827593 Free PMC article. Review.
-
Extractive-liquid sampling electron ionization-mass spectrometry (E-LEI-MS): a new powerful combination for direct analysis.Sci Rep. 2023 Apr 20;13(1):6429. doi: 10.1038/s41598-023-33647-5. Sci Rep. 2023. PMID: 37081134 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous