Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2001 Aug;91(2):717-24.
doi: 10.1152/jappl.2001.91.2.717.

Multiple firing of single muscle vasoconstrictor neurons during cardiac dysrhythmias in human heart failure

Affiliations
Free article

Multiple firing of single muscle vasoconstrictor neurons during cardiac dysrhythmias in human heart failure

M Elam et al. J Appl Physiol (1985). 2001 Aug.
Free article

Abstract

Single vasoconstrictor nerve fibers in humans normally fire only once but have the capacity to fire as many as eight times, per cardiac interval. Our laboratory recently demonstrated that the mean firing frequency of individual vasoconstrictor fibers is more than doubled in the sympathoexcitation associated with congestive heart failure (Macefield VG, Rundqvist B, Sverrisdottir YB, Wallin BG, and Elam M. Circulation 100: 1708--1713, 1999). However, the propensity to fire only once per cardiac interval was retained. In the present retrospective study, we tested the hypothesis that vasoconstrictor fibers fire more than once per cardiac interval in response to transient sympathoexcitatory stimuli, providing one mechanism for further increase of an already augmented sympathetic discharge. Six patients with congestive heart failure (New York Heart Association functional class II--IV; left ventricular ejection range 13--37%, average 22%) were studied at rest and during premature ectopic heartbeats. Analyzed for a total of 60 premature beats, the average firing probability of 10 vasoconstrictor fibers increased from 61 to 80% in the prolonged cardiac interval (i.e., reduced diastolic pressure) after premature beats. The incidence of multiple within-burst firing increased markedly, with two spikes being more common than one. Our results illustrate two different mechanisms (increases in firing probability and multiple within-burst firing), and indirectly indicate a third mechanism (recruitment of previously silent fibers), for acute sympathoexcitatory responses.

PubMed Disclaimer

Publication types

LinkOut - more resources