Mechanism of antithrombogenicity of a new heparinized hydrophilic polymer: chronic in vivo studies and clinical application
- PMID: 1146018
Mechanism of antithrombogenicity of a new heparinized hydrophilic polymer: chronic in vivo studies and clinical application
Abstract
A new heparinized hydrophilic polymer, H-RSD (graftcopolymer composed of ethylene, vinyl acetate, vinyl chloride, polyethyleneglycolmethacrylate, quartenized dimethylaminoethylmethacrylate and ionically bound heparin), continuously releases heparin from its surface at the rate of approximately 0.004 units/cm2/min when placed in the plasma. It has excellent antithrombogenic and mechanical properties for a biomaterial. In vivo evaluation for thrombogenically using IVC indwelling catheter method in dogs revealed excellent antithrombogenicity over 2 wks. Use of H-RSD as a coating material on other synthetic polymers has also been studied, Catheters made of polyurethane were coated with H-RSD 20 mu, 50 mu, 100 mu, and 150 mu in thickness, and were tested for thrombogenicity in the dog. Catheters coated with 20 mu of H-RSD caused moderate to severe thrombus in the IVC after 2 wks, but catheters coated with H-RSD 50 mu or more were completely free of thrombus formation after 2 wks. Scanning electron micrograph showed neither fibrin clots nor platelet adhesion on the surface of H-RSD catheters. Heparin concentration in H-RSD catheters was analyzed by electron probe X-ray microanalyzer before and after in vivo tests. Heparin concentration became higher as the thickness of H-RSD coating increased. After a 2 wk test, heparin concentration in the catheters decreased to about 85% of the initial value. Good retention of heparin in the H-RSD catheters after in vivo tests was found to correlate with continuous release of heparin from its surface. H-RSD catheters can be sterilized with ethylene oxide gas. Pyrogen and acute toxicity tests on extracts of H-RSD were negative. H-RSD catheters were used in 9 patients for up to 3 wks. Thrombus formation observed by pullout venography or at autopsy in these patients was less than those seen in patients with silicone rubber or polyethylene catheters.
Similar articles
-
[In vivo evaluation of the new antithrombogenic reservoir-catheter coated with polymer blend copolymer].Nihon Igaku Hoshasen Gakkai Zasshi. 1997 Apr;57(5):238-43. Nihon Igaku Hoshasen Gakkai Zasshi. 1997. PMID: 9164111 Japanese.
-
Permeability of heparinized hydrophilic polymer (H-RSD): application to semipermeable membrane for microencapsulation of activated charcoal.J Biomed Mater Res. 1982 Jan;16(1):17-30. doi: 10.1002/jbm.820160105. J Biomed Mater Res. 1982. PMID: 7056759
-
Development of Anthron, an antithrombogenic coating for angiographic catheters.J Biomater Appl. 1989 Jul;4(1):3-21. doi: 10.1177/088532828900400101. J Biomater Appl. 1989. PMID: 2746467
-
The Production of Solid Dosage Forms from Non-Degradable Polymers.Curr Pharm Des. 2016;22(19):2738-60. doi: 10.2174/1381612822666160217141049. Curr Pharm Des. 2016. PMID: 26898737 Review.
-
Design of nonthrombogenic polymer surfaces for blood-contacting medical devices.Blood Purif. 1996;14(5):357-72. doi: 10.1159/000170288. Blood Purif. 1996. PMID: 8894131 Review.
Cited by
-
Hydrophilic polymer gel.Forensic Sci Med Pathol. 2014 Mar;10(1):148-9. doi: 10.1007/s12024-013-9479-6. Epub 2013 Sep 20. Forensic Sci Med Pathol. 2014. PMID: 24052433 No abstract available.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Research Materials