Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2001 Aug;20(2):233-8.
doi: 10.1016/s1010-7940(01)00769-2.

Usefulness of vacuum-assisted cardiopulmonary bypass circuit for pediatric open-heart surgery in reducing homologous blood transfusion

Affiliations

Usefulness of vacuum-assisted cardiopulmonary bypass circuit for pediatric open-heart surgery in reducing homologous blood transfusion

K Nakanishi et al. Eur J Cardiothorac Surg. 2001 Aug.

Abstract

Objective: Open-heart surgery without homologous blood transfusion is still difficult in children because priming volume in cardiopulmonary bypass circuit results in extreme hemodilution. Vacuum-assisted cardiopulmonary bypass circuit has the benefit of improving venous return and results in lowering priming volume. We introduced vacuum-assisted cardiopulmonary bypass circuit in order to reduce priming volume for pediatric patients in March 1995. A retrospective study was made on the efficacy of vacuum-assisted circuit for pediatric open-heart surgery in reducing homologous blood transfusion.

Methods: Patients weighing from 5 to 20 kg who underwent surgery between January 1991 and June 1996 were divided into two groups, group A comprised 128 patients before introduction of this circuit and group B comprised 49 patients after introduction, and their clinical course was compared. Vacuum-assisted circuit was used in 27 patients of group B.

Results: The percentage of transfusion-free operations was significantly higher in group B than in group A (33.6% in group A vs. 53.1% in group B, P = 0.014), and particularly this percentage in patients weighing less than 10 kg significantly increased (0% in group A vs. 42.9% in group B, P < 0.01). The amount of homologous blood transfusion was significantly lower in group B than in group A (374 +/- 362 ml in group A and 212 +/- 287 ml in group B, P < 0.01). The rate of complications and the duration of respiratory support did not differ between the two groups. The duration of hospital stay was lower in group B than in group A.

Conclusions: The findings of this study indicate that vacuum-assisted circuit is useful for pediatric open-heart surgery in reducing homologous blood transfusion.

PubMed Disclaimer