Frequency of overinstrumentation with an acceptable radiographic working length
Abstract
The aim of this in vitro study was to determine how frequent a seemingly accurate working length ending radiographically 0 to 2 mm short of the radiographic apex resulted in an instrumentation beyond the apical foramen. Under simulated clinical conditions working lengths of 169 root canals were radiographically determined in 91 extracted teeth. In all cases the measuring files adjusted to the final working length (Iwork) were located 0 to 2 mm short of the radiographic apex. Iwork was subsequently compared with the actual reference length (Iref) representing the distance between the apical foramen and the coronal reference. Instrumentation beyond the apical foramen (Iwork > ref) occurred in premolars in 51% (95% confidence interval: 36%; 66%) of the cases, in molars in 22% (95% confidence interval: 14%; 30%), and in anterior teeth in no case. These results suggest that in premolars and molars a radiographically working length ending 0 to 2 mm short of the radiographic apex provides, more often than expected, a basis for unintentional overinstrumentation.
Similar articles
-
The validity of cone-beam computed tomography in measuring root canal length using a gold standard.J Endod. 2013 Dec;39(12):1607-10. doi: 10.1016/j.joen.2013.08.001. Epub 2013 Sep 24. J Endod. 2013. PMID: 24238457
-
The ability of root ZX apex locator to reduce the frequency of overestimated radiographic working length.J Endod. 2002 Feb;28(2):116-9. doi: 10.1097/00004770-200202000-00017. J Endod. 2002. PMID: 11833683
-
Effect of using electronic apex locators on selected endodontic treatment parameters.J Endod. 2000 Jun;26(6):364-7. doi: 10.1097/00004770-200006000-00013. J Endod. 2000. PMID: 11199756 Clinical Trial.
-
[Electronic determination of the length of the root canal].Rev Belge Med Dent (1984). 1999;54(4):259-81. Rev Belge Med Dent (1984). 1999. PMID: 12723167 Review. French.
-
[Problems with working length determination during endodontic therapy].Fogorv Sz. 2006 Aug;99(4):153-9. Fogorv Sz. 2006. PMID: 17016923 Review. Hungarian.
Cited by
-
[Confusion and solution for root canal working length determination].Hua Xi Kou Qiang Yi Xue Za Zhi. 2016 Apr;34(2):109-14. doi: 10.7518/hxkq.2016.02.001. Hua Xi Kou Qiang Yi Xue Za Zhi. 2016. PMID: 27337916 Free PMC article. Chinese.
-
In vitro evaluation of Root ZX and Raypex 6 in teeth with different apical diameters.J Conserv Dent. 2015 Jan-Feb;18(1):66-9. doi: 10.4103/0972-0707.148899. J Conserv Dent. 2015. PMID: 25657531 Free PMC article.
-
Evaluation of electrical impedance ratio measurements in accuracy of electronic apex locators.Restor Dent Endod. 2015 May;40(2):113-22. doi: 10.5395/rde.2015.40.2.113. Epub 2014 Dec 26. Restor Dent Endod. 2015. PMID: 25984472 Free PMC article.
-
Clinicians' perspectives, inducements, preferences, and clinical experiences regarding the use of electronic apex locator and apex locator integrated engine-driven instrumentation: a cross-sectional study.BMC Oral Health. 2024 Aug 14;24(1):939. doi: 10.1186/s12903-024-04710-y. BMC Oral Health. 2024. PMID: 39143627 Free PMC article.
-
Evaluation of the multifrequency electronic apex locator Joypex 5 in primary teeth.Eur Arch Paediatr Dent. 2014 Feb;15(1):51-4. doi: 10.1007/s40368-013-0065-0. Epub 2013 Jul 24. Eur Arch Paediatr Dent. 2014. PMID: 23881737
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous