Clinical Trial
. 2001 Aug;12(8):951-5.
doi: 10.1016/s1051-0443(07)61575-9.

Recombinant tissue plasminogen activator (alteplase) for restoration of flow in occluded central venous access devices: a double-blind placebo-controlled trial--the Cardiovascular Thrombolytic to Open Occluded Lines (COOL) efficacy trial

Affiliations
Clinical Trial

Recombinant tissue plasminogen activator (alteplase) for restoration of flow in occluded central venous access devices: a double-blind placebo-controlled trial--the Cardiovascular Thrombolytic to Open Occluded Lines (COOL) efficacy trial

D Ponec et al. J Vasc Interv Radiol. 2001 Aug.

Abstract

Purpose: Central venous access devices (CVADs) are a mainstay of current medical therapy but often become occluded by thrombus. Tissue plasminogen activator (alteplase), at a dose of 2 mg per 2 mL, has been shown to be effective in restoring flow to catheters proven by radiographic contrast injection to be occluded by thrombus. The purpose of this double-blind placebo-controlled multicenter trial was to determine the efficacy of alteplase in occluded catheters without earlier contrast injections or radiographic examinations.

Materials and methods: Patients were eligible for inclusion if blood could not be withdrawn from their catheter after a period of normal function of at least 48 hours. Single or multiple catheters, peripherally inserted central catheters, catheters with valves, and implanted ports were eligible; catheters used for hemodialysis were not included. Patients were randomly assigned to one of two groups. In one group, patients received a first dose of 2 mg alteplase followed, if needed, by a second dose of 2 mg alteplase and a third dose of placebo. The other group received placebo first followed by one 2-mg dose of alteplase and then a second, if needed. Each dose was allowed to dwell for 2 hours and ability to withdraw blood from the catheter was reassessed. The endpoint was restoration of the ability to withdraw and infuse through the catheter. One hundred forty-nine patients were randomized: 74 received placebo first, 75 received alteplase first.

Results: After the first 2-hour treatment, function was restored to 74% in the alteplase arm and 17% in the placebo arm (P <.0001 compared to placebo). After one or two treatments, function was restored in 90% of patients. There were no serious study-drug-related adverse events, no intracranial hemorrhage, no major hemorrhage, and no embolic events.

Conclusion: Infusion of alteplase appeared to be safe and effective in restoring flow to occluded catheters without need for pretreatment radiographic evaluation.