Accuracy and precision of dual-energy X-ray absorptiometry for body composition measurements in rhesus monkeys
- PMID: 11491410
- DOI: 10.1034/j.1600-0684.2001.300204.x
Accuracy and precision of dual-energy X-ray absorptiometry for body composition measurements in rhesus monkeys
Abstract
Accuracy of body composition measurements by dual-energy X-ray absorptiometry (DXA) was compared with direct chemical analysis in 10 adult rhesus monkeys. DXA was highly correlated (r-values > 0.95) with direct analyses of body fat mass (FM), lean mass (LM) and lumbar spine bone mineral content (BMC). DXA measurements of total body BMC were not as strongly correlated (r-value = 0.58) with total carcass ash content. DXA measurements of body FM, LM and lumbar spine BMC were not different from data obtained by direct analyses (P-values > 0.30). In contrast, DXA determinations of total BMC (TBMC) averaged 15%, less than total carcass ash measurements (P = 0.002). In conclusion, this study confirms the accurate measurement of fat and lean tissue mass by DXA in rhesus monkeys. DXA also accurately measured lumbar spine BMC but underestimated total body BMC as compared with carcass ash determinations.
Similar articles
-
Pediatric body composition analysis with dual-energy X-ray absorptiometry.Pediatr Radiol. 2009 Jul;39(7):647-56. doi: 10.1007/s00247-009-1247-0. Epub 2009 May 5. Pediatr Radiol. 2009. PMID: 19415261 Review.
-
Composition analysis of pork carcasses by dual-energy x-ray absorptiometry.J Anim Sci. 1998 Aug;76(8):2104-14. doi: 10.2527/1998.7682104x. J Anim Sci. 1998. PMID: 9734860
-
Precision and accuracy of dual-energy X-ray absorptiometry for determining in vivo body composition of mice.Obes Res. 2000 Aug;8(5):392-8. doi: 10.1038/oby.2000.47. Obes Res. 2000. PMID: 10968731
-
Fan beam dual energy X-ray absorptiometry body composition measurements in piglets.J Am Coll Nutr. 2003 Oct;22(5):408-14. doi: 10.1080/07315724.2003.10719324. J Am Coll Nutr. 2003. PMID: 14559933
-
The impact of recent technological advances on the trueness and precision of DXA to assess body composition.Obesity (Silver Spring). 2012 Jan;20(1):30-9. doi: 10.1038/oby.2011.211. Epub 2011 Jul 14. Obesity (Silver Spring). 2012. PMID: 21760631 Review.
Cited by
-
Relationship of insulin, glucose, leptin, IL-6 and TNF-α in human breast milk with infant growth and body composition.Pediatr Obes. 2012 Aug;7(4):304-12. doi: 10.1111/j.2047-6310.2012.00059.x. Epub 2012 May 10. Pediatr Obes. 2012. PMID: 22577092 Free PMC article.
-
Validation of a body condition scoring system in rhesus macaques (Macaca mulatta): assessment of body composition by using dual-energy X-ray absorptiometry.J Am Assoc Lab Anim Sci. 2012 Jan;51(1):88-93. J Am Assoc Lab Anim Sci. 2012. PMID: 22330874 Free PMC article.
-
Pediatric body composition analysis with dual-energy X-ray absorptiometry.Pediatr Radiol. 2009 Jul;39(7):647-56. doi: 10.1007/s00247-009-1247-0. Epub 2009 May 5. Pediatr Radiol. 2009. PMID: 19415261 Review.
-
The precision study of dual energy X-ray absorptiometry for bone mineral density and body composition measurements in female cynomolgus monkeys.Quant Imaging Med Surg. 2022 Mar;12(3):2051-2057. doi: 10.21037/qims-21-799. Quant Imaging Med Surg. 2022. PMID: 35284275 Free PMC article.
-
Radiographic incidence of spinal osteopathologies in captive rhesus monkeys (Macaca mulatta).Comp Med. 2010 Oct;60(5):396-9. Comp Med. 2010. PMID: 21262126 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Research Materials
Miscellaneous