A technique for adequate coverage of the proximal suture line during abdominal aortic aneurysm repair
- PMID: 11496295
- DOI: 10.1067/mva.2001.115805
A technique for adequate coverage of the proximal suture line during abdominal aortic aneurysm repair
Abstract
The proximal suture line is a vulnerable area after abdominal aortic aneurysm repairs. This area has been implicated in various postoperative complications, such as pseudoaneurysm formation, graft-enteric fistula, and suture line disruption. We present a technique that provides safe and adequate coverage of this suture line by using the aneurysm sac. This technique is derived from the z-plasty technique used for scar revision. The technique is illustrated with detailed line drawings. None of the patients in whom we used this technique have had any complications related to the proximal suture line.