Comparative Study
. 2001 Aug;38(2):486-92.
doi: 10.1016/s0735-1097(01)01393-6.

Noninvasive quantitative tissue characterization and two-dimensional color-coded map of human atherosclerotic lesions using ultrasound integrated backscatter: comparison between histology and integrated backscatter images

Affiliations
Free article
Comparative Study

Noninvasive quantitative tissue characterization and two-dimensional color-coded map of human atherosclerotic lesions using ultrasound integrated backscatter: comparison between histology and integrated backscatter images

M Kawasaki et al. J Am Coll Cardiol. 2001 Aug.
Free article

Abstract

Objectives: The purpose of the present study was to define clinicopathologically whether integrated backscatter (IB) combined with conventional two-dimensional echo (2DE) can differentiate the tissue characteristics of calcification (CL), fibrosis (FI), lipid pool (LP) with fibrous cap, intimal hyperplasia (IH) and thrombus (TH) and can construct two-dimensional tissue plaque structure in vivo.

Background: It is difficult to characterize the components of plaque using conventional 2DE techniques.

Methods: Integrated backscatter values of plaques were measured in the right common carotid and femoral arteries (total 24 segments) both during life and after autopsy in 12 patients (age 68 to 84 years, 10 men and two women). Integrated backscatter values were determined using a 5-12 MHz multifrequency transducer, setting the region of interests (ROIs) (11 x 11 pixels) on the echo tomography of the entire arterial wall (55 +/- 10 ROI/segment) and comparing it with histologic features in the autopsied arterial specimens.

Results: Corrected IB values obtained before death and at autopsy were significantly correlated (r = 0.93, p < 0.01). Corresponding to the histologic features, corrected IB values on the rectangle ROIs obtained during life were divided into five categories: category 1 (TH) 4 < IB < or = 6; category 2 (media and IH or LP in the intima) 7 < IB < or = 13; category 3 (FI) 13 < IB < or = 18, category 4 (mixed lesion) 18 < IB < or = 27 and category 5 (CL) 28 < IB < or = 33. In category 2, media and intima were differentiated using conventional 2DE. Under the above procedures, color-coded maps constructed with IB-2DE obtained during life precisely reflected the histologic features of media and intima.

Conclusions: Integrated backscatter with 2DE represents a useful noninvasive tool for evaluating the tissue structure of human plaque.

PubMed Disclaimer

Publication types

LinkOut - more resources