Ultrasonic examination: an alternative to chest radiography after central venous catheter insertion?
- PMID: 11500340
- DOI: 10.1164/ajrccm.164.3.2009042
Ultrasonic examination: an alternative to chest radiography after central venous catheter insertion?
Abstract
We evaluated ultrasonic examination as a diagnostic tool for catheter misplacement and pneumothorax after central venous catheter insertion. Physicians in the intensive care unit (ICU) performed the ultrasonic examinations, and the results were compared with those of chest radiography. Eighty-five central venous catheters (70 subclavian and 15 internal jugular) were inserted into 81 patients; 10 misplacements and one pneumothorax occurred. Ultrasonic examination feasibility was 99.6%. The only pneumothorax and all misplacements except one were diagnosed by ultrasound. Taking into consideration misplacements and pneumothorax research, ultrasonic examination did not give any false positive results. The mean time of the entire ultrasonic examination was 6.8 +/- 3.5 min, whereas 80.3 +/- 66.7 min were needed for the radiography (p < 0.0001). This study has suggested that ultrasonic diagnosis of catheter misplacement and pneumothorax related to central venous catheterization is a rapid and accurate method that can be easily performed by ICU physicians.
Similar articles
-
Ultrasound localization of central vein catheter and detection of postprocedural pneumothorax: an alternative to chest radiography.Crit Care Med. 2010 Feb;38(2):533-8. doi: 10.1097/CCM.0b013e3181c0328f. Crit Care Med. 2010. PMID: 19829102
-
Is Routine Chest X-Ray After Ultrasound-Guided Central Venous Catheter Insertion Choosing Wisely?: A Population-Based Retrospective Study of 6,875 Patients.Chest. 2018 Jul;154(1):148-156. doi: 10.1016/j.chest.2018.02.017. Epub 2018 Mar 6. Chest. 2018. PMID: 29501497
-
Fast Track ultrasound protocol to detect acute complications after totally implantable venous access device placement.Ann Surg Oncol. 2015;22(6):1943-9. doi: 10.1245/s10434-014-4222-4. Epub 2014 Nov 18. Ann Surg Oncol. 2015. PMID: 25404473
-
[How to improve central venous catheter use in intensive care unit?].Ann Fr Anesth Reanim. 2006 Feb;25(2):180-8. doi: 10.1016/j.annfar.2005.07.079. Epub 2005 Oct 14. Ann Fr Anesth Reanim. 2006. PMID: 16226862 Review. French.
-
Delayed tension pneumothorax complicating central venous catheterization and positive pressure ventilation.Am J Emerg Med. 1995 Sep;13(5):532-5. doi: 10.1016/0735-6757(95)90164-7. Am J Emerg Med. 1995. PMID: 7662057 Review.
Cited by
-
The "rapid atrial swirl sign" for assessing central venous catheters: Performance by medical residents after limited training.PLoS One. 2018 Jul 16;13(7):e0199345. doi: 10.1371/journal.pone.0199345. eCollection 2018. PLoS One. 2018. PMID: 30011285 Free PMC article.
-
Central catheter tip migration in critically ill patients.PLoS One. 2022 Dec 19;17(12):e0277618. doi: 10.1371/journal.pone.0277618. eCollection 2022. PLoS One. 2022. PMID: 36534662 Free PMC article.
-
Comparison of intraoperative ultrasonography guidance with an open surgical method for venous port catheter placement in chemotherapy.North Clin Istanb. 2018 Nov 28;6(3):279-283. doi: 10.14744/nci.2018.76992. eCollection 2019. North Clin Istanb. 2018. PMID: 31650116 Free PMC article.
-
Lung ultrasound in the critically ill.Ann Intensive Care. 2014 Jan 9;4(1):1. doi: 10.1186/2110-5820-4-1. Ann Intensive Care. 2014. PMID: 24401163 Free PMC article.
-
Ultrasound-Guided Placement of Central Venous Port Systems via the Right Internal Jugular Vein: Are Chest X-Ray and/or Fluoroscopy Needed to Confirm the Correct Placement of the Device?World J Surg. 2016 Oct;40(10):2353-8. doi: 10.1007/s00268-016-3574-2. World J Surg. 2016. PMID: 27216807
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical