Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2001 Mar;30(3):161-8.
doi: 10.1007/s001320050590.

[Significance of static prosthesis alignment for standing and walking of patients with lower limb amputation]

[Article in German]
Affiliations

[Significance of static prosthesis alignment for standing and walking of patients with lower limb amputation]

[Article in German]
S Blumentritt et al. Orthopade. 2001 Mar.

Abstract

The influence of three alignment parameters of a transtibial prosthesis (sagittal foot position, plantar flexion, mediolateral foot position) on the load and motion of the lower extremity joints was investigated in 13 unilateral transtibial amputees. The aim was to determine whether a correlation exists between static prosthetic alignment and gait pattern that would allow an optimal biomechanical prosthetic alignment. The gait pattern was measured using kinematic, kinetic, and electromyographic methods. Statics was defined using the alignment apparatus L.A.S.A.R. Posture. The electromyogram of the m. vastus lateralis and m. biceps femoris was recorded on both sides. The motion of joints is described by joint angles. External joint moments define the mechanical loads. Alignment has almost no influence on muscle activity and joint mechanics of the contralateral leg. In contrast, prosthetic alignment affects clearly and systematically the load and motion of the knee joint during the stance phase on the ipsilateral side. The sagittal foot position influences the maximal flexion angle in the stance phase. The plantar flexion of the foot affects the temporal structure of knee motion. The mediolateral foot position causes correspondingly different varus and valgus moments acting on the knee. Swing phase motion does not depend on prosthetic alignment. The iEMG of the m. vastus lateralis is reduced. Innervation characteristics of the m. biceps femoris on the prosthetically fitted leg has completely changed. The ischiocrural muscles take over the neuromuscular action of the m. gastrocnemius to compensate for the external knee extension moment during the second part of the stance phase. Prosthetic statics determines if the knee joint is physiologically stressed in a standing posture and during walking. Statics will be correct if the anatomical knee axis of the standing amputee is located about 15 mm posterior to the load line in the sagittal plane. In the frontal plane, the load line touches the lateral patella border and strikes the middle of the foot about 5 cm anterior to the adapter. During walking, attention should be paid to performance of knee flexion in the stance phase.

PubMed Disclaimer

Publication types

LinkOut - more resources