Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2001 Jul-Aug;84(4):1035-44.

Comparison of liquid chromatography/mass spectrometry, ELISA, and phosphatase assay for the determination of microcystins in blue-green algae products

Affiliations
  • PMID: 11501902
Comparative Study

Comparison of liquid chromatography/mass spectrometry, ELISA, and phosphatase assay for the determination of microcystins in blue-green algae products

J F Lawrence et al. J AOAC Int. 2001 Jul-Aug.

Abstract

More than 100 samples of blue-green algae products (consisting of Aphanizomenon, Spirulina, and unidentified blue-green algae) in the form of pills, capsules, and powders were collected from retail outlets from across Canada. The samples were extracted with 75% methanol in water and centrifuged to remove solids. Aliquots of the extracts along with spiked blank sample extracts were sent to each participating laboratory and independently analyzed for microcystins by enzyme-linked immunosorbent assay (ELISA), protein phosphatase inhibition assay, and by liquid chromatography-tandem mass spectrometry (LC-MS/MS) after sample cleanup using C18 solid-phase extraction. The results obtained by ELISA and LC-MS/MS agreed very well over a concentration range of about 0.5-35 microg/g. The colorimetric phosphatase results generally agreed with the other 2 methods. While the 2 biochemical assays measured total microcystin content compared with a standard of microcystin LR, the LC-MS/MS method measured specific microcystins (LA, LR, RR, YR) using external standards of these for identification and quantitation. Microcystin LR was found in all positive samples by LC-MS/MS. Microcystin LA was the only other microcystin found in the samples analyzed. These 2 microcystins represent essentially all the microcystins that were present in the extracts. Otherwise, the LC-MS/MS results would have been significantly lower than the results of the biochemical assays had other unknown microcystins been present.

PubMed Disclaimer

Similar articles

Cited by

Publication types

MeSH terms