Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2001 Aug;50(8):661-8.

Screening for microalbuminuria to prevent nephropathy in patients with diabetes: a systematic review of the evidence

Affiliations
  • PMID: 11509158

Screening for microalbuminuria to prevent nephropathy in patients with diabetes: a systematic review of the evidence

D C Scheid et al. J Fam Pract. 2001 Aug.

Abstract

Objective: Our goal was to evaluate whether screening patients with diabetes for microalbuminuria (MA) is effective according to the criteria developed by Frame and Carlson and those of the US Preventive Services Task Force.

Study design: We searched the MEDLINE database (1966-present) and bibliographies of relevant articles.

Outcomes measured: We evaluated the impact of MA screening using published criteria for periodic health screening tests. The effect of the correlation between repeated tests on the accuracy of a currently recommended testing strategy was analyzed.

Results: Quantitative tests have reported sensitivities from 56% to 100% and specificities from 81% to 98%. Semiquantitative tests for MA have reported sensitivities from 51% to 100% and specificities from 21% to 100%. First morning, morning, or random urine sampling appear feasible. Assuming an individual test sensitivity of 90%, a specificity of 90%, and a 10% prevalence of MA, the correlation between tests would have to be lower than 0.1 to achieve a positive predictive value for repeated testing of 75%.

Conclusions: Screening for MA meets only 4 of 6 Frame and Carlson criteria for evaluating screening tests. The recommended strategies to overcome diagnostic uncertainty by using repeated testing are based on expert opinion, are difficult to follow in primary care settings, do not improve diagnostic accuracy sufficiently, and have not been tested in a controlled trial. Although not advocated by the American Diabetes Association, semiquantitative MA screening tests using random urine sampling have acceptable accuracy but may not be reliable in all settings.

PubMed Disclaimer

Comment in

Similar articles

Cited by

Publication types

MeSH terms

Substances

LinkOut - more resources